CLEAN AND INSPECT DAILY

Disconnect tool from air supply before cleaning and

inspection. Correct all problems before placing the tool back in use.

Wipe tool clean and inspect for wear or damage. Use non-flammable
cleaning solutions to wipe exterior of tool only if necessary. DO NOT SOAK
tool with cleaning solutions. Such solutions can damage internal parts.

Inspect trigger and safety mechanism to assure system is complete and
functional: no loose or missing parts, no binding or sticking parts.

Keep all screws tight. Loose screws can cause personal injury or damage
tool.

If tool is used without an in-line oiler: place 5 or 6 drops of Air Tool Oil into
the air inlet of the tool at the beginning of each workday.

CLEARING A JAMMED FASTENER

Disconnect tool from air supply.

1.

Open magazine and remove remaining fasteners (Fig. 26 and Fig. 27).

NOTE: 

Remove fasteners from tool before opening the fastener

guide plate. Fasteners are under pressure and may shoot out of
magazine which could cause injury.

2.

Depress

the quick release latch and open the fastener guide plate 

(Fig. 28).

3.

Remove the jammed fastener (Fig. 29).

4.

Depress 

the quick release latch and close the fastener guide plate.

Fig. 27

Fig. 26

Fig. 29

Fig. 28

MAINTENANCE

Summary of Contents for Ex-Cell A05983

Page 1: ...Power Company Part No A05983 07 22 04 Owners Manual for models ENS100 ENS150 Staplers Record All Information and attach sales receipt here for future reference Purchase Date _________________________...

Page 2: ...bre d ordre TABLE OF CONTENTS SAFETY GUIDELINES AND INSTRUCTIONS 3 GENERAL SAFETY RULES 4 6 FUNCTIONAL DESCRIPTION 7 PREPARING THE TOOL 8 OPERATING INSTRUCTIONS 9 10 MAINTENANCE 10 SERVICE 11 TROUBLES...

Page 3: ...ways be followed to reduce the risk of personal injury Improper operation maintenance or modification of tools or equipment could result in serious injury and property damage There are certain applica...

Page 4: ...hanism is bumped while the trigger is depressed 4 Choice of triggering method is important Check manual for triggering options See Using the Tool section of this manual 5 Never point tool at yourself...

Page 5: ...ever use tool if safety trigger or springs are inoperable missing or damaged Do not alter or remove safety trigger or springs Make daily inspections for free movement of trigger and safety mechanism F...

Page 6: ...n With Contact Actuation tools an unwanted fastener will be fired if the safety mechanism is allowed to recontact work surface before trigger is released 26 Do not drive fasteners on top of other fast...

Page 7: ...ior trim paneling cabinetry picture mirror frames and crafts Features include jam release mechanism tool free adjustable exhaust fastener reload indicator safety positioned on rear of nose and a remov...

Page 8: ...th points up in the magazine channel B Fig 20 NOTE Staples are loaded from the bottom 4 Push magazine core closed Fig 21 5 Observe the low fastener indicator A Fig 22 and reload as needed 6 Adjust dir...

Page 9: ...astener is driven This single sequential actuation method provides the most accurate fastener placement Disconnect tool from air supply before performing maintenance clearing a jammed fastener leaving...

Page 10: ...ews tight Loose screws can cause personal injury or damage tool If tool is used without an in line oiler place 5 or 6 drops of Air Tool Oil into the air inlet of the tool at the beginning of each work...

Page 11: ...ply before performing any Service Procedure SYMPTOM PROBLEMS SOLUTIONS 1 Air leak near top of Loose screws Tighten screws tool or in trigger area Worn or damaged Install Overhaul Kit o rings or seals...

Page 12: ...oes not receive satisfactory results from the Authorized Warranty Service Center the purchaser should contact DeVilbiss Air Power Company THIS WARRANTY DOES NOT COVER Merchandise sold as reconditioned...

Reviews: