Rectifying faults
Error messages (power source)
099-005670-EW501
7.03.2022
51
Error 53: No wire feeder 2
Category B
Wire feeder 2 was not detected.
Check the control cable connections.
Error 54: VRD error
Error in the open-circuit voltage reduction.
If necessary, disconnect the external machine from the welding circuit.
Request service.
Error 55: Excess current of the wire feeder
Category B
Excess current detected in the wire feed mechanism.
Do not lay the liner in tight radii.
Check the liner for smooth movement.
Error 56: Mains phase failure
One phase of the mains voltage has failed.
Check mains connection, mains plug and mains fuses.
Error 57: Slave tacho error
Category B
Fault in the wire feeder (slave drive).
Check the connections (connectors, lines).
Permanent overload of the wire drive (slave drive).
Do not lay the liner in tight radii.
Check the liner for smooth movement.
Error 58: Short circuit
Category B
Short circuit in the welding circuit.
Eliminate the short circuit in the welding circuit.
Place the welding torch on an insulated surface.
Error 59: Incompatible machine
A machine connected to the system is not compatible.
Disconnect the incompatible machine from the system.
Error 60: Incompatible software
The software of a machine is not compatible.
Disconnect the incompatible machine from the system
Request service.
Error 61: Welding monitoring
The actual value of a welding parameter is outside the specified tolerance range.
Maintain the tolerance ranges.
Adjust the welding parameters.
Error 62: System component
The system component was not found.
Request service.