Design and function
Network connection
099-005674-EW501
28.06.2022
35
5.6.1 Connection
Equipment damage or faults may occur if the PC is connected incorrectly!
Not using the SECINT X10USB interface results in equipment damage or faults in signal trans-
mission. The PC may be destroyed due to high frequency ignition pulses.
• Interface SECINT X10USB must be connected between the PC and the welding machine!
• The connection must only be made using the cables supplied (do not use any additional ex-
tension cables)!
Figure 5-15
Item Symbol Description
0
1
Connection socket (9-pole) - D-Sub
PC interface
2
Connection cable, 9-pole, serial
3
SECINT X10 USB
4
USB connection
Connecting a Windows PC to SECINT X10 USB
5
Windows PC
5.7 Network connection
This accessory component is only available as a “factory-fit option”.
The network connection allows the integration of the product into an existing network and exchanging
data using the quality-management software Xnet. Some features of the software:
• Real-time display of the welding parameters
• Recording / documentation
• Monitoring of welding parameters
• Maintenance
• Calculations
• WPS management
• Welder management
• xButton management
• Component management
The functionality of the software is in constant development (see the documentation for Xnet).
As standard, welding machines are supplied with a fixed IP address.
Depending on the machine version, the IP address is displayed in the device control or shown on a sti-
cker either below the rating plate or near the control.
The gateway and the server / computer must be in the same network or IP address range to allow
the configuration of the gateway.