Rectifying faults
Warnings
52
099-005674-EW501
28.06.2022
Warning
Potential cause / remedy
2
Half-wave failures
Check process parameters.
3
Torch cooling warning
Check coolant level and top up if necessary.
4
Shielding gas
Check shielding gas supply.
5
Coolant flow
Check min. flow rate.
[2]
6
Wire reserve
Only a small amount of wire is left on the spool.
7
CAN bus failure
Wire feeder not connected; automatic circuit-breaker of wire
feed motor (reset the tripped automatic circuit-breaker by actu-
ating).
8
Welding circuit
The inductance of the welding circuit is too high for the selected
welding task.
9
WF configuration
Check WF configuration.
10
Partial inverter
One of several partial inverters is not supplying welding current.
11
Excess temperature of the coo-
lant
[1]
Check temperature and switching thresholds.
[2]
12
Welding monitoring
The actual value of a welding parameter is outside the specified
tolerance field.
13
Contact error
The resistance in the welding circuit is too high. Check earth
connection.
14
Alignment error
Switch the machine off and on. If the error persists, notify Ser-
vice.
15
Mains fuse
The power limit of the mains fuse is reached and the welding
power is reduced. Check the fuse setting.
16
Shielding gas warning
Check the gas supply.
17
Plasma gas warning
Check the gas supply.
18
Forming gas warning
Check the gas supply.
19
Gas warning 4
reserved
20
Coolant temperature warning Check coolant level and top up if necessary.
21
Excess temperature 2
reserved
22
Excess temperature 3
reserved
23
Excess temperature 4
reserved
24
Coolant flow warning
Check coolant supply.
Check coolant level and top up if necessary.
Check flow and switching thresholds.
[2]
25
Flow 2
reserved
26
Flow 3
reserved
27
Flow 4
reserved
28
Wire stock warning
Check wire feeding.
29
Low wire 2
reserved
30
Low wire 3
reserved
31
Low wire 4
reserved
32
Tacho error
Fault of wire feeder - permanent overload of the wire drive.
33
Excess current on the wire feed
motor
Excess current detected on wire feed motor.