Design and function
TIG Synergic operating principle
84
099-000115-EW501
17.06.2015
5.13.16.2 TIG up/down torch (8-pole)
Up/down torch with one torch trigger
Diagram
Operating
elements
Explanation of symbols
TT 1 = torch trigger 1
Functions
Mode
Operating
elements
Welding current on/off
1
(factory-
set)
Secondary current (tapping mode) / (latched mode)
Increase welding current, infinite adjustment (up function)
Reduce welding current, infinite adjustment (down function)
Welding current on/off
2
Secondary current (tapping mode)
Welding current on/off
4
Secondary current (tapping mode) / (Latched mode)
Increase welding current by an increment *
Reduce welding current by an increment *