5.3.17 Expert menu (TIG)
The Expert menu has adjustable
parameters stored that don’t require regular setting. The number of pa-
rameters shown may be limited, e.g. if a function is deactivated.
ENTER
4s
EXIT
4s
Figure 5-46
Display
Setting/selection
Expert menu
Slope time (main current to secondary current)
Slope time (main current to secondary current)
Amplitude balance
> see 5.3.9 chapter
activArc parameter
Parameter also adjustable after TIG activArc welding is activated.
Filler wire process (cold/hot wire)
-----
filler wire activated
-----
filler wire deactivated (factory setting)
Hot wire process (start signal for hot wire power source)
------- Function enabled
------- Function disabled (ex works)
Wire/pulse function (wire feeding behaviour when using pulsed TIG welding)
Wire feeding can be disabled during pulse pauses (not the case for automated
pulsing or kHz pulsing).
------- Function disabled
------- Function enabled (ex works)