Machine description
– quick overview
Machine control
– Operating elements
26
099-000109-EW501
23.08.2018
4.3.1
Function sequence
Figure 4-6
Item Symbol
Description
0
1
Select welding parameters button
This button is used to select the welding parameters depending on the welding process
and operating mode used.
2
Gas pre-flow time signal light
3
AMP%
Signal light
Ignition current
(TIG)/hot start current
(MMA)
4
sec
Signal light
Up-slope time
(TIG)/hot start time
(MMA)
5
AMP
Main current (TIG) / pulse current
I min to I max (1 A increments)
Main current (MMA)
I min to I max (1 A increments)
6
sec
Pulse break time/slope time from AMP to AMP%
• Pulse break setting range: 0.01 sec to 20.0 sec
(0.01 sec increments < 0.5 sec; 0.1 sec increments > 0.5 sec)
• Slope time (tS1) setting range: 0.0 sec to 20.0 sec
> see 5.3.13 chapter
TIG pulses: The pulse break time applies to the secondary current phase (AMP%)
TIG AC Special: The pulse break time applies to the DC phase with AC special.
7
AMP%
Secondary current / pulse pause current
8
sec
Pulse time / slope time from AMP% to AMP
• Pulse time setting range: 0.01 s to 20.0 s
(0.01 s increments < 0.5 s; 0.1 s increments > 0.5 s)
• Slope time (tS2) setting range: 0.0 s to 20.0 s
> see 5.3.13 chapter
TIG pulses
The pulse time applies to the main current
phase (AMP) for pulses.
TIG AC Special
The pulse time applies to the AC phase for
AC special.
9
sec
Down-slope time (TIG)
10
AMP%
End-crater current signal light
11
Signal light, gas post-flow time
12
Balance signal light
AC balance (TIG)/pulse balance (TIG DC
– kHz pulses)/pulse balance (MMA)