Design and function
TIG welding
44
099-000099-EW501
29.08.2014
Figure 5-18
As an example the process is shown with HF ignition. Arc ignition with lift arc is also possible, however
"See 5.8.5 Arc ignition chapter".
Sequence:
• Press and hold torch trigger 1.
• The gas pre-flow time elapses.
• HF ignition pulses jump from the electrode to the workpiece, the arc ignites.
• The welding current flows and immediately assumes the value set for the ignition current I
start
.
• HF is switched off.
• The welding current increases in the adjusted up-slope time to the main current AMP.
NOTE
The process ends when the set spotArc time elapses or if the torch trigger is released
prematurely.
spotArc/pulse variants table:
Process
Pulse variants
TIG DC
Automated pulses (factory setting)
(lights up in green)
Pulses (thermal pulses)
(lights up in red)
kHz pulse (metallurgic pulses)
No pulses