5.8.3
Select welding task
NOTE
Machine control provides the user with up to 8 welding tasks (JOBs).
JOB 0 represents manual operating mode. This is where you can change/optimise all
parameters directly in machine control "See 5.8.3.1 Manual, standard operation (JOB 0)
chapter".
5.8.3.1
Manual, standard operation (JOB 0)
NOTE
It is only possible to change the basic welding parameters if:
• No welding current is flowing and
• The key switch (option) is set to position “1”.
"Manual, standard operation (JOB 0)" is set by default on delivery and every time the machine control is
reset. This means that the welder repeatedly makes all the required welding settings and re-adjusts them
for each individual welding task.
Operating
element
Action Result
Select and display welding process
TIG welding
Select and display operating mode
spotArc (spot time setting range 0.01 sec. to 20.0 sec.)
Non-latched
Latched
Select and display pulse procedure
TIG automated pulses (frequency and balance)
TIG pulses with times, lights up in green/fast TIG DC pulses with
frequency and balance, lights up in red
Select welding parameter in the functional sequence
Set welding parameters