Design and function
TIG welding
099-000229-EW501
14.04.2015
31
5.7.2.2 Setting the shielding gas quantity
Rule of thumb for the gas flow rate:
Diameter of gas nozzle in mm corresponds to gas flow in l/min.
Example: 7mm gas nozzle corresponds to 7l/min gas flow.
Incorrect shielding gas setting!
• If the shielding gas setting is too low or too high, this can introduce air to the weld pool and
may cause pores to form.
• Adjust the shielding gas quantity to suit the welding task!
5.7.2.3 Gas test
Operating
element
Action
Result
x x
Press the "Select welding parameter" button until the "activArc" LED
activArc flashes.
5 sec.
Press the "Select welding parameter" button and hold for approx. 5 sec.
The gas pre-flow time LED (TIG) will come on,
shielding gas flows for approx. 20 sec.
• Set the required shielding gas quantity at the pressure regulator.