Design and function
MIG/MAG welding
099-005214-EW501
19.05.2011
35
5.7.6.5
Accessory components for operating point setting
The operating point setting can also be made with the accessory components
• R11/RG11 remote control
• Up/Down torch with two rockers (2 U/D)
You will find an overview of accessory components in the "Accessories" chapter. See the operating
instructions for the machine in question for a more detailed description of the individual machines and
their functions.
5.7.7
MIG/MAG welding data display
Taurus Basic S
V
AMP
6
4
1
5
3
2
Figure 5-11
Item Symbol Description
0
1
Signal light, AMP
During welding, the left display shows the actual welding current value.
After welding, the welding current hold value is displayed.
2
Signal light, WF
The left display shows the nominal value for the wire feed
3
Display, left
Welding current as actual value or hold value,
wire-feed speed as nominal value.
4
Display, right
Welding voltage
5
Signal light, coolant fault
Low coolant level
6
Signal light, excess temperature
Excess temperature, welding machine