Appendix A
Parameter overview
– setting ranges
46
099-00T406-EW501
13.07.2017
6
Appendix A
6.1
Parameter overview
– setting ranges
6.1.1
TIG welding
Name
Display
Setting range
Code
Standa
rd
Unit
Mi
n.
Max.
Main current AMP, depending on power source
-
A
-
-
-
Gas pre-flow time
0,5
s
0,1
-
5
Ignition current, percentage of AMP
20
%
1
-
200
Ignition current, absolute, depending on power source
-
A
-
-
-
Up-slope time
1,0
s
0,0
-
20,0
Pulse current
140
%
1
200
Secondary current, percentage of AMP
50
%
1
200
Secondary current, absolute, depending on power source
-
A
-
-
Down-slope time
1,0
s
0,0
-
20,0
End current, percentage of AMP
20
%
1
-
200
End current, absolute, depending on power source
-
A
-
-
-
Gas post-flow time
8
s
0,1
-
20,0
Electrode diameter, metric
1,6
mm
1,0
-
4,0
spotArc time
2
s
0,01 -
20,0
spotmatic time (
>
)
200
ms
5
-
999
spotmatic time (
>
)
2
s
0,01 -
20,0
AC balance
1
65
%
40
-
90
Pulse balance
50
%
1
-
99
Pulse frequency (DC)
2,8
Hz
0,2
-
2000
Pulse frequency (AC)
1
2,8
Hz
0,2
-
5
AC frequency
1
50
Hz
50
-
200
activArc
50
0
-
100
Dynamic power adjustment
16
A
16
-
20
1
for AC welding machines only.