Functional characteristics
Machine configuration menu
42
099-00T406-EW501
13.07.2017
Display
Setting/selection
Exit the menu
Exit
Torch configuration menu
Set welding torch functions
Torch mode (ex works 1)
> see 4.1.9.2 chapter
Up/down speed
> see 4.1.9.3 chapter
Increase value > rapid current change
Decrease value > slow current change
Current jump
> see 4.1.9.4 chapter
Current jump setting in ampere
Machine configuration
Settings for machine functions and parameter display
Absolute value setting (ignition, secondary, end and hot start cur-
rent)
> see 3.2.1 chapter
------- Welding current setting, absolute
------- Welding current setting, as a percentage of the main current (ex works)
TIG antistick
> see 4.1.8 chapter
------- function active (factory setting).
------- function inactive.
Time-based power-saving mode
> see 4.3 chapter
Time to activation of the power-saving mode in case of inactivity.
Setting
=
disabled or numerical value 5
– 60 min. (ex works: 20).
Pulsed TIG welding (thermic) in the upslope and downslope pha-
ses
> see 4.1.6.1 chapter
------ Function enabled (ex works)
------ Function disabled
TIG HF start (soft/hard) switching
------- soft ignition (factory setting).
------- hard ignition.
spotmatic operating mode
> see 4.1.5.5 chapter
Ignition by contact with the workpiece
------- Function enabled (ex works)
------- Function disabled
Spot time setting
> see 4.1.5.5 chapter
------- Short spot time, setting range 5 ms to 999 ms, increments of 1 ms (ex works)
------- Long spot time, setting range 0.01 s to 20.0 s, increments of 10 ms (ex works)
Process activation setting
> see 4.1.5.5 chapter
------- Separate process activation (ex works)
------- Permanent process activation
Access block menu
Protect welding parameters against unauthorised access.
Machine code
Querying the three-digit machine code (000 to 999), user input
Switch off
Switching off machine function
Switch on
Switching on machine function
Error