Functional characteristics
TIG welding
26
099-00T406-EW501
13.07.2017
Pulse balance
Figure 4-17
Pulse frequency
Figure 4-18
4.1.6.1 Pulsed welding in the upslope and downslope phases
The pulse function can also be deactivated if necessary during the up-slope and down-slope
phases (parameter
) > see 4.6 chapter.
Figure 4-19
4.1.6.2 Automated pulses
The automated pulsing pulse variant is only activated for DC welding in combination with the spotArc ope-
rating mode. The current-dependent pulse frequency and balance create vibrations in the weld pool that
have a positive effect on the gap bridging. The required pulse parameters are automatically defined by
the machine control. If required, the function can be disabled by pressing the pulsed welding push-button.