Functional characteristics
TIG welding
099-00T401-EW501
01.02.2022
43
5.1.9.9 RETOX TIG torch (12-pole)
These accessory components can be retrofitted as an option .
Figure
Operating elements
Explanation of symbols
BRT = torch trigger
Functions
Mode
Operating ele-
ments
Welding current on/off
1
(ex works)
BRT 1
Secondary current
BRT 2
Secondary current (tapping function)
BRT 1 (tapping)
Increase welding current (up function)
BRT 3
Decrease welding current (down function)
BRT 4
Modes 2 and 3 are not used in this torch type or are not useful.
Welding current on/off
4
BRT 1
Secondary current
BRT 2
Secondary current (tapping function)
BRT 1 (tapping)
Increase welding current in steps (setting of the 1st step)
BRT 3
Decrease welding current in steps (setting of the 1st step)
BRT 4
Switching between Up/Down and JOB use
BRT 2 (tapping)
Increase JOB number
BRT 3
Decrease JOB number
BRT 4
Gas test
BRT 2 (3 s)
Welding current on/off
6
BRT 1
Secondary current
BRT 2
Secondary current (tapping function)
BRT 1 (tapping)
Increase welding current continuously (up function)
BRT 3
Decrease welding current continuously (down function)
BRT 4
Switching between Up/Down and JOB use
BRT 2 (tapping)
Increase JOB number
BRT 3
Decrease JOB number
BRT 4
Gas test
BRT 2 (3 s)
5.1.9.10 Specifying max. no. of accessible JOBs
This function allows the user to define the maximum number of retrievable JOBs in free memory. The fac-
tory setting is 101 JOBs that are retrievable with the welding torch; this value can be reduced if required.
The first JOB is factory-set to JOB 0. The first JOB can be set as desired. The following graphic shows an
example with the settings max. retrievable JOBs = 5 and first retrievable JOB = 20. This results in the ret-
rievable JOBs 20 to 24.
Figure 5-27
Display
Setting/selection
Start JOB
Set the first retrievable JOB (setting: 0 to 101, factory-set to 0).