Functional characteristics
Filler wire welding
099-00T401-EW501
01.02.2022
55
5.3.5 Operating modes (functional sequences)
The welding current operating mode must be set to latched on the welding machine. The welding
current is infinitely adjustable by means of torch triggers 3 and 4 (BRT 3 and BRT 4). Torch trigger
2 (BRT 2) switches the welding current on or off.
Torch trigger 1 (BRT 1) switches the wire feed on or off. The operator can choose between three
operating modes (see following function sequences).
Figure 5-42
5.3.5.1 Explanation of symbols
Symbol Meaning
Press torch trigger
Release torch trigger
Tap torch trigger (press briefly and release)
Shielding gas flowing
I
Welding output
Gas pre-flows
Gas post-flows
Non-latched
Latched
t
Time
P
START
Ignition program
P
A
Main program
P
B
Reduced main program
P
END
End program
tS1
Slope duration from PSTART to PA
Wire feed