Functional characteristics
TIG welding
Item No.: 099-002046-EWM01
27
5.1.6
Torch mode and up/down speed setting
The user has the modes 1 to 3 and modes 11 to 13 available. Modes 11 to 13 include the same function
options as 1 to 3, but without tapping function for the secondary current.
The function options in the individual modes can be found in the tables for the corresponding torch types.
Figure 5-6
Display Setting/selection
Calibration
The machine will be calibrated for approx 2 seconds each time it is switched on.
Exit the menu
Exit
Software version of the machine control
Version display (example 2.4 = version 2.4)
Torch configuration menu
Set welding torch functions
Torch mode
• Modes 1-3: with tapping function (factory setting 1)
• Modes 11-13: without tapping function
Up-/Down speed (not available in modes 3 and 13)
Increase value
= rapid current change (factory setting 10)
Reduce value
= slow current change
*
Tapping function:
Tap briefly on the torch trigger to initiate a function change, e.g. changeover from main to
secondary current (for more in-depth information, see chapter "Setting the torch mode and
up/down speed").
NOTE
Only the modes listed are suitable for the corresponding torch types.