1
Technical data
1/1
inverter
with
S
-sign
TIG 150 DC
TIG 200 DC
powerSinus
TIG 250 DC
TIG 300 DC
Adjustable:
Welding current
5A - 150A
5A - 200A
5A - 250A
5A - 300A
Welding voltage
10,1V - 26V
10V - 28V
10V - 30V
10V - 32V
Mains voltage
(tolerances)
1x230V (15%;-40%)
1x240V (10%;-40%)
1x230V (15%;-40%)
1x240V (10%;-40%)
3x400V (20%;-25%)
3x415V (15%;-25%)
3x400V (20%;-25%)
3x415V (15%;-25%)
Mains frequency
50/60Hz
Mains fuse
slow-blow
1 x 16A
1 x 16A
3 x 16A
3 x 16A
Welding current
TIG / MMA
25%duty cycle
- / 150A
- / 200A
- / -
- / -
35%duty cycle
150A / -
200A / -
- / -
- / -
40%duty cycle
- / -
- / -
- / -
300A / 300A
60%duty cycle
116A / 97A
150A / 130A
250A / 250A
250A / 250A
100%duty cycle
90A / 75A
120A / 100A
190A / 190A
190A / 190A
Load alternation
10min (60% duty cycle
∧
6 min welding, 4min break)
Workpiece
35mm
2
50mm
2
Open circuit voltage
100V
75V
106V
106V
Efficiency
85%
89%
cos phi
0,99
1,0
0,99
0,99
Ambient temperature
-10
°
C bis +40
°
C
Protection
classification
IP 23
Insulation class
H
Machine cooling
fan
Torch cooling
gas
Total weight
23kg
22kg
26kg
26kg
Dimensions (LxBxH)
450x290x400mm
530x260x400mm
480x355x400mm
480x355x400mm
Constructed to
standards
VDE 0544 und EN 60974-1
S
All welding machines which carry the
S
marking are constructed in accordance
with VDE 0544 (EN 60974-1) and can be used in working with increased hazard
of electrical shock
1.1
Area of application:
This machines are suitable exclusively for:
•
TIG DC welding with HF and Liftarc ignition of all metals except aluminium.
•
MMA DC welding.
All welding machines which carry the
S
marking are constructed in accordance with VDE 0544
(EN 60974-1) and can be used in working with increased hazard of electrical shock