background image

11

2551 Blind Magmeter

Plastic Installation Fittings for Metric Pipes:

Polypropylene True Union Tees and Wafers
PVDF True Union Tees, PVC True Union Tees

Metal Installation Fittings

Iron Saddles

PIPE 
SIZE 

(IN.)

FITTING 

TYPE

PULSE 

/ U.S. 

GAL

PULSE / 

LITERS

"GPM at 

20mA

Factory 

setting "

"LPM at 

20mA

Factory 

setting "

POLYPROPYLENE FITTINGS (DIN/ISO, BS, ANSI)

DN15

PPMT005

2192.73

579.32

16

62

DN20

PPMT007

1327.81

350.81

26

98

DN25

PPMT010

737.16

194.76

43

162

DN32

PPMT012

453.46

119.81

66

250

DN40

PPMT015

275.03

72.66

104

392

DN50

PPMT020

164.17

43.37

164

623

PVDF FITTINGS (DIN/ISO, BS, ANSI)

DN15

SFMT005

1946.49

514.26

16

62

DN20

SFMT007

1158.05

305.96

28

106

DN25

SFMT010

749.09

197.91

46

174

DN32

SFMT012

439.51

116.12

77

292

DN40

SFMT015

248.93

65.77

121

456

DN50

SFMT020

146.85

38.80

202

766

PVC FITTINGS (DIN/ISO, BS, ANSI)

DN15

PVMT005

2067.76

546.30

18

68

DN20

PVMT007

1136.61

300.29

28

106

DN25

PVMT010

716.52

189.31

46

174

DN32

PVMT012

446.07

117.85

72

272

DN40

PVMT015

278.83

73.67

113

428

DN50

PVMT020

159.36

42.10

179

677

PIPE 
SIZE 

(IN.)

FITTING 

TYPE

PULSE 

/ U.S. 

GAL

PULSE 

LITERS

"GPM at 

20mA

Factory 

setting"

"LPM at 

20mA

Factory 

setting"

SCH 80 IRON SADDLE ON SCH 80 PIPE

2

IR8S020

194.85

51.48

151

572

2-1/2

IR8S025

142.28

37.59

217

820

3

IR8S030

87.53

23.13

338

1278

4

IR8S040

40.62

10.73

588

2225

5

IR8S050

29.28

7.74

930

3521

6

IR8S060

22.30

5.89

1333

5045

8

IR8S080

12.52

3.31

2335

8838

10

IR8S100

7.94

2.10

3673

13905

12

IR8S120

5.65

1.49

5197

19672

SCH 80 IRON SADDLE ON SCH 40 PIPE

2

IR8S020

185.35

48.97

172

651

2-1/2

IR8S025

127.47

33.68

245

927

3

IR8S030

76.62

20.24

378

1433

4

IR8S040

40.23

10.63

652

2469

5

IR8S050

27.32

7.22

1024

3877

6

IR8S060

19.71

5.21

1480

5601

8

IR8S080

11.61

3.07

2557

9680

10

IR8S100

7.36

1.94

4032

15262

12

IR8S120

5.18

1.37

5725

21671

Calibration Data: K-Factors and Full Scale Current Values

Summary of Contents for Neptune Benson Defender FP Series

Page 1: ...INSTALLATION FOSS SWIM SCHOOL AND ACCESSORIES ELMWOOD PARK FILTER SYSTEM an QUA brand evo 334 Knight St Suite 3100 West Warwick RI 02886 800 832 8002 401 821 2200 Fax 401 821 7129 E mail infowebsite...

Page 2: ...M LYNCH 14DEC21 INIT DYMNYR FOSS SWIM SCHOOL ELMWOOD PARK SWIMMING POOL FOSS SWIM SCHOOL LLC 35452 1 1 1 18 GPM SQ FT 252 GPM NTS...

Page 3: ...Defender FP Series Featuring PowerBump System Installation and Operation Manual Phone 800 832 8002 Web www neptunebenson com www defenderfilter com...

Page 4: ...tallation 16 Operation 17 System Requirements 17 Pre Startup Check 17 Performing a Dry Test 17 Performing a Quick Start 18 Loading Media into the System Precoat Process Vacuum Transfer 18 Entering Fil...

Page 5: ...wer bump valve V3 Power bump valve V4 Power bump valve V5 Precoat valve V6 Vacuum transfer valve V7 Vacuum vent valve V8 Vacuum hose valve V9 Tank drain valve V10 Check Valve 4 or 6 V11 In line sight...

Page 6: ...tial of skin burn injury exists when handling or servicing the pnuematic actuators and pump when on or shortly after stopping the system Use caution around the system and avoid the heated areas during...

Page 7: ...to the floor Anchors must be installed per the manufacturer s instructions before attempting to lift the filter head top plate Failure to properly bolt the filter to the floor can result in bodily inj...

Page 8: ...nting bracket by inserting the longer flange bolts through the channel in the bracket and secure with 0 75 inch nuts included 4 Bolt the gauge panel to the mounting bracket using four 0 25 x 1 inch sc...

Page 9: ...4 Control Enclosure and Filter Regulator 0 5 inch hard pipe from compressor Do not use PVC not included 0 5 inch shut off valve not included 0 5 inch instant fitting 0 5 inch hose to solenoid Manifol...

Page 10: ...t protection supplied by others Recommended protection is 120 230 VAC 15 10 A Line Power Connect to TERMINAL 100 Neutral Connect to TERMINAL 100A Ground Connect to GROUND LUG located at the upper righ...

Page 11: ...fected parts 1 Attach the filter regulator to a wall using anchors compatible with the type of wall construction Block plaster wood etc The anchors are not included 2 Add an isolation valve before the...

Page 12: ...Page 10 26 Rev 01 18 2021 Installing the Butterfly Valves...

Page 13: ...Page 11 26 Rev 01 18 2021 Making the Pneumatic Actuator Tubing Connections Figure 7 Pneumatic Tubing Diagram...

Page 14: ...pneumatic actuators as included in valve kit 1002 1214 1002 1543 If using any other actuator consult your system designer on proper actuator installation Air to OPEN valve Valve disc position indicat...

Page 15: ...trix NOTE After making pneumatic actuator connections raise the air pressure to 90 psi and confirm the valve positions match the Idle state presented in the valve matrix table above If a valve state i...

Page 16: ...Control Valves Adjustment Figure 11 Flow Control Valves Pneumatic actuators are provided with the flow control valves The flow control valves connected to the pneumatic actuators are used to regulate...

Page 17: ...s for smooth operation To make this adjustment 1 The control valve on the closed port regulates the butterfly valve s opening speed 2 The control valve on the open port regulates the butterfly valve s...

Page 18: ...Rev 01 18 2021 Vacuum Transfer Unit Installation Figure 12 Vacuum transfer setup NOTE Most standard shop style vacuums will be appropriate for loading media A vacuum can be provided by Neptune Benson...

Page 19: ...ed Refer to Installing the Control Panel and Filter Regulator Set the filter regulator to 90 PSI 6 2 Bar Pump rotates in the proper direction and is ready to run Performing a Dry Test 2 With the pump...

Page 20: ...lve V6 10 Open the 0 75 inch precoat vent line valve F6 and 1 5 inch vacuum drain line valve V7 11 Open pump discharge throttling valve F7 and purge the air from the system NOTE If the filter is below...

Page 21: ...load and other factors the media might require recharging anywhere between 2 weeks and 3 months The exact frequency will become apparent as operating experience with the system increases The following...

Page 22: ...Every 3 months Refer to the manufacturer s owner s manual for details When replacing the airline filter element use SMC Corporation Part AF40P 060S Flexible tube cleaning Varies depending on bather l...

Page 23: ...y turning the switch on the PowerBump Control Panel to the left OFF 2 Loading Media into the System Precoat Process Vacuum Transfer 3 Purge the air from the system 4 Switch to Filter Mode 5 Precoat fo...

Page 24: ...nother gasket on top of the tube sheet assembly 12 Place the filter head onto the gasket 13 Connect the filter head to the tank using the fasteners with 1 1 8 wrench Tighten the fasteners to 20 ft lb...

Page 25: ...Page 23 26 Rev 01 18 2021 Parts List Assembly Exploded View Figure 15 Exploded View 8 3 6 7 5 4 2 17 16 15 13 14 11 12 10 4 9 1 20 22 21 18 19 22 23 24...

Page 26: ...ENDER TUBE ELEMENT 36 T316 366 1000 7552 10 TUBESHEET PLATE PVC BOTTOM FP SERIES 1 1002 1160 11 HOLD DOWN PLATE PVC TUBESHEET FP SERIES 1 1002 1161 12 GASKET FELT F TUBESHEET COMPACT DEFENDER 1 1002 1...

Page 27: ...assembly into the flange pipe so that the flow openings are facing downward inside the filter 3 Install a second gasket between the diffuser and flange connected to the installation piping 4 Tighten...

Page 28: ...n presented herein is believed reliable and in accordance with accepted engineering practices Evoqua makes no warranties as to the completeness of this information Users are responsible for evaluating...

Page 29: ...magnetic ow sensor The patented sensor design is available in a variety of corrosion resistant materials to provide long term reliability and minimal maintenance costs Wetted material combinations inc...

Page 30: ...20 F C 4 32 68 104 140 176 212 248 Operating Temperature Pressure Dimensions Refer to your local Georg Fischer Sales o ce for the most current warranty statement All warranty and non warranty repairs...

Page 31: ...nd 316L SS T0 T1 T2 PVDF and Titanium V0 V1 V2 PVDF and Hastelloy C O rings FKM standard EPDM FFKM optional The user is responsible for determining the chemical suitability of these materials for a sp...

Page 32: ...GF OK OK OK Vertical flow is OK if the pipe remains full at all times Type Description Plastic tees 0 5 in to 2 in versions MPVC or CPVC PVC Glue on Saddles 10 in and 12 in only Cut 2 in hole in pipe...

Page 33: ...Earth Ground Terminal Flow Important The directional arrow on the sensor body MUST be pointed DOWNSTREAM for correct operation Digital S3 L and 4 to 20 mA will not work if ow is against direction of...

Page 34: ...metal clamps on metal pipes Fluid grounds must be in direct contact with the uid and as near to the Magmeter as possible 3 The shield from the output cable must be terminated at the remote instrument...

Page 35: ...to indicate reverse ow The maximum cable length from the 2551 to the 8900 or 9900 depends on the 8900 or 9900 con guration Refer to the 8900 9900 or 9950 manual for complete information Blue Jumper O...

Page 36: ...d performance settings are pre set to meet the requirements of most applications The 2551 application and performance settings can be customized using the Signet 3 0252 Con guration Tool and software...

Page 37: ...stallation limitations No Averaging With AVERAGING set to zero the ow rate will be displayed immediately and with no ltering This line represents the actual output of the ow sensor as it responds to u...

Page 38: ...VC TEES FOR SCH 80 CPVC PIPE 1 2 MCPV8T005 2496 03 659 45 12 45 3 4 MCPV8T007 1381 48 364 99 22 84 1 MCPV8T010 857 98 226 68 37 139 1 1 4 MCPV8T012 445 17 117 61 66 248 1 1 2 MCPV8T015 325 56 86 01 90...

Page 39: ...DN15 PVMT005 2067 76 546 30 18 68 DN20 PVMT007 1136 61 300 29 28 106 DN25 PVMT010 716 52 189 31 46 174 DN32 PVMT012 446 07 117 85 72 272 DN40 PVMT015 278 83 73 67 113 428 DN50 PVMT020 159 36 42 10 17...

Page 40: ...67 378 1433 4 CS4W040 36 38 9 61 652 2469 5 CS4W050 29 28 7 73 1024 3877 6 CS4W060 20 29 5 36 1480 5601 8 CS4W080 11 73 3 10 2557 9680 10 CS4W100 7 45 1 97 4032 15262 12 CS4W120 5 24 1 39 5725 21671 G...

Page 41: ...agmeter Use 3 0252 Setup tool to re span the Magmeter to match Loop device Re span Loop device to match Magmeter Range Jumper not placed correctly Set Range Jumper correctly Defective Magmeter Return...

Page 42: ...empty pipe Frequency output will be locked to 0 Hz if electrodes are not wet Digital S3 L output will be locked to 0 if electrodes are not wet 4 to 20 mA will be locked to 4 mA if electrodes are not...

Page 43: ...placement Electronics Module 3 2551 11 159 001 215 Magmeter electronics frequency or digital S3 L output 3 2551 12 159 001 216 Magmeter electronics 4 to 20 mA output 3 2551 21 159 001 372 Magmeter dis...

Page 44: ...8 in PVDF and Hastelloy C 3 2551 P2 12 159 001 112 DN250 to DN900 10 to 36 in Polypropylene and 316L SS 3 2551 T2 12 159 001 449 DN250 to DN900 10 to 36 in PVDF and Titanium 3 2551 V2 12 159 001 451...

Page 45: ...lve V6 3 Open Precoat Line Vent Valve F6 50 4 Open Vacuum Vent Valve V7 50 5 Open Pump Discharge Throttling Valve F7 6 Turn Filter Switch ON on Control Panel 7 Close Vacuum Vent Valve V7 when water ex...

Reviews: