GENERAL INSTALLATION
5.1
The pump must be located as close as practical to the pool. The pump must also be in a
position that enables easy access for periodic servicing.
5.2
Care must also be taken to position the pump in an area that is free from flooding in a
well-ventilated and dry location.
5.3
The pump motor cooling fan must have a minimum clearance of 150mm (6”).
5.4
The pump suction line should be not smaller than 40mm (1.5”).
5.5
The suction line is to have as few bends or elbows as possible. There must not be an air
trap on the suction line.
5.6
Use only the pump barrel unions supplied with the pump.
5.7
Ensure the pump is securely fastened to a level surface in the required position to
prevent movement.
5.8
The pump electrical cable must be wired for the proper voltage and rotation in
accordance with the wiring instructions.
5.9
All wiring and electrical work must be carried out by licensed electricians and installed
in accordance with applicable local codes.
5.10
The motor must be grounded.
5.11
The weight of the plumbing and fittings is to be independently supported and not
carried by the pump.