Evolution Evoflow TUF Installation And Operation Manual Download Page 6

4

7.0 

MAINTENANCE

7.1 

The hair and lint pot should be inspected and cleaned at regular intervals. The procedure 
for inspection and cleaning is as follows:

1.  Remove the lid and lift out the hair and lint pot. 
 
2.  Remove debris and hose off with clean water if necessary. 
 
3.  Inspect the lid gasket, lubricate with silicon-based grease only if needed. If it is 
damaged, replace. 
 
4.  Replace the hair and lint pot.  
 
5.  Reprime the hair and lint pot bowl. 
 
6.  Correctly locate the o-ring. 
 
7.  Replace the lid, hand tight only. 
 
8.  Switch on pump.

7.2 

In climates where the pump may be exposed to frost or freezing, care must be taken 
to ensure the pump is protected from damage. It is recommended that if the pump is 
not used during this winter period, it should be drained completely. Drain plugs can be 
supplied for this purpose. The winterising procedure is as follows:

1.  Drain the pump.

2.  Do not replace the drain plug. Store it in a safe place until you require the use of the 
pump. An example would be within the hair and lint pot bowl basket.

3.  If possible, remove the pump and store it in a dry location during this period.

4. When you reactivate the pump, ensure all seals and o-rings are in operational 
condition and replace them if necessary—Regrease o-rings and gaskets with silicon-
based grease on refitting.

5.  Check that the motor shaft moves freely before reactivation.

6.  Reprime pump as per 

6.0 Priming.

Summary of Contents for Evoflow TUF

Page 1: ...echnician Improper installation can create electrical hazards which could result in property damage serious injury or death Improper installation will void the warranty This manual contains important...

Page 2: ...t exceeding 30mA be installed 2 5 Check the pumps nameplate for the following Voltage Amp draw and Cycle 2 6 The powercord includingthe groundwire shallhave a qualityof60245 IEC 66 H07RN F for models...

Page 3: ...level of safety The manufacturer of the pump assumes no liability for the damage and injuries caused by unauthorised replacement parts and accessories 4 7 During operation some parts of the pump are...

Page 4: ...s to have as few bends or elbows as possible There must not be an air trap on the suction line 5 6 Use only the pump barrel unions supplied with the pump 5 7 Ensure the pump is securely fastened to a...

Page 5: ...start the pump Operating the pump with these valves shut can damage the pump 6 5 Start the pump 6 6 Allow a few minutes maximum for the pump to start delivering water 6 7 iWARNING High suction lift or...

Page 6: ...must be taken to ensure the pump is protected from damage It is recommended that if the pump is not used during this winter period it should be drained completely Drain plugs can be supplied for this...

Page 7: ...locked line Refer to Pump will not prime Motor runs hot Be aware some heat from motors is normal Do not touch hot motors Thermal overload protector will deactivate pump if there is an overload or high...