EvoHeat Fusion-i Series Manual 

4. Safety Instructions 

Installation, repair or relocations must be done by a fully qualified person and not by the customer. If done 

incorrectly it may cause fire, electric shock, water leakage and other hazards. 

A circuit breaker must be installed for the unit. 
To avoid risk of electrical shock, the unit must have a good power connection and earthing. 

The unit is equipped with an over-load protection system. After a previous stoppage, the unit will not start for at 

least 3 minutes. 

Do not use any means to accelerate the defrosting processor or to clean other than those 

recommended by the manufacturer. 

The unit must be stored in a room without any continuously operating ignition sources 

(for example: open flames, an operating gas appliance or an operating electric heater.) 

Do not pierce or burn.  

Be aware that refrigerants may not contain an odour. 

If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified 

persons in order to avoid a hazard. 

The appliance shall be installed in accordance with national wiring regulations. 

Before obtaining access to terminals, all supply circuits must be disconnected. 

An all-pole disconnection device must be incorporated which as at least 3mm clearances in all poles, a leakage 

current that may exceed 10mA, residual current device (RCD) having a rated residual operating current not 

exceeding 30mA and disconnection must be incorporated in the fixed wiring in accordance with the wiring rules. 

The unit should be installed, operated and stored in a room with a floor area larger than 30m2. 

-

 

The installation of pipe-work shall be kept to a minimum 30 m2  

-

 

Spaces where refrigerant pipes shall be compliance with national gas regulations.  

-

 

Servicing shall be performed only as recommended by the manufacturer.  

-

 

The appliance shall be stored in a well-ventilated area where the room size corresponds to the room area as 

specified for operation. 

-

 

All working procedure that affects safety means shall only be carried by competent persons. 

Transport of equipment containing flammable refrigerants  

-

 

Compliance with the transport regulations  

-

 

Marking of equipment using signs 

-

 

Compliance with local regulations  

-

 

Disposal of equipment using flammable refrigerants 

-

 

Compliance with national regulations  

-

 

Storage of equipment/appliances  

-

 

The storage of equipment should be in accordance with the manufacturer's instructions.  Storage of packed 

(unsold) equipment  

-

 

Storage package protection should be constructed such that mechanical damage to the equipment inside 

the package will not cause a leak of the refrigerant charge.  

-

 

The maximum number of pieces of equipment permitted to be stored together will be determined by local 

regulations. 

Use supply wires suitable for 75°C 
* Caution: Single wall heat exchanger, not suitable for potable water connection. 

 

Summary of Contents for Fusion-i 12

Page 1: ......

Page 2: ..._________________ 12 6 2 Functions of the Controller _____________________________________________________________________ 13 6 2 1 Start up Shutdown __________________________________________________...

Page 3: ...h minimal running costs Designed with the latest technology including stepless full DC inverter compressors fans and control systems the Evo Fusion i is the energy efficient and environmentally friend...

Page 4: ...3 EvoHeat Fusion i Series Manual 2 Unit Dimensions Unit mm Fusion i 7 9 12...

Page 5: ...4 EvoHeat Fusion i Series Manual Fusion i 16 Fusion i 19...

Page 6: ...rubber pads under the feet of the unit 3 Install the supplied condensation barb to the underside of the unit and direct the condensation to an appropriate drainage point PLUMBING INSTALLATION PLEASE...

Page 7: ...tart within 60 seconds 4 To select the operating mode press the M button to cycle to the sun icon heating 5 To set the temperature press in the main interface the current target temperature will flash...

Page 8: ...0mA residual current device RCD having a rated residual operating current not exceeding 30mA and disconnection must be incorporated in the fixed wiring in accordance with the wiring rules The unit sho...

Page 9: ...censed installer will void the warranty Correct installation is required to ensure safe and efficient operation of your pool heater Before installation it is very important to ensure 5 variables are c...

Page 10: ...of to be forced through the unit A water deflector may be needed to protect the heat pump If installing the heater on an existing pump filtration system the heater must be installed AFTER the filter a...

Page 11: ...flow than required to the heat pump 5 6 Rubber Feet All EvoHeat units are provided with rubber feet which EvoHeat highly recommend being installed The rubber feet help reduce vibration of the unit and...

Page 12: ...read the information before connecting Ensure the power cable and circuit breaker are of a suitable size for the heater being installed Also check that there is adequate voltage and current available...

Page 13: ...is locked HEATING Heating mode is active FAULT Displays when a fault occurs AUTO Auto mode is active WIRELESS Appears if the unit is connected to wifi and shows the strength of the signal accordingly...

Page 14: ...rding to what mode is active After 2 seconds without a change the setting will be saved If the unit is defrosting the defrosting symbol will display on the main interface After defrosting is complete...

Page 15: ...e is no operation for 20 seconds the system will automatically memorise the settings and return to the main menu Press the ON OFF button at any time during changes to exit without saving changes 6 2 5...

Page 16: ...n to activate the one click silent function If the one click silent and timing silent function are both started at the same time press MUTE to cancel the one click silent unction and quit the timing s...

Page 17: ...s from the main menu hold the ON OFF button for around 5 seconds The keyboard will be locked when the small lock symbol appears The screen can be locked while the controller is in the on or off interf...

Page 18: ...freezing Prot E29 The ambient temp Is low Inlet and outlet temp too big E06 Water flow is not enough and low differential pressure Check the pipe water flow and whether water system is jammed or not...

Page 19: ...e input voltage measurement Inv Sampling Volt F11 The input voltage sampling fault Check and adjust the current measurement Comm Err DSP PFC F12 DSP and PFC connect fault Check the communication conne...

Page 20: ...19 EvoHeat Fusion i Series Manual 8 Appendix 8 1 Interface Drawings 1 Main Board Fusion i7 Fusion i9 Fusion i12...

Page 21: ...20 EvoHeat Fusion i Series Manual 2 Main board Fusion i16 Fusion i19...

Page 22: ...HT System exhaust temperature input 20 P00 GND Earth wire 21 P01 GND Earth wire 22 P13 L P14 L Electric reactor 23 R485 B R485 A Color line controller communication 24 CN15 Electronic Expansion valve...

Page 23: ...m2 25mm2 125A 101 123A 2 x 35mm2 35mm2 160A 123 148A 2 x 50mm2 50mm2 225A 148 186A 2 x 70mm2 70mm2 250A 186 224A 2 x 95mm2 95mm2 280A If the unit is to be installed outdoors ensure that a UV resistant...

Page 24: ...should I be checking regularly Check the water inlet outlets often for leaks You should avoid the condition of no water or air entering into the system as this will influence unit s performance and r...

Page 25: ...sible ignition sources including cigarette smoking should be kept sufficiently far away from the site of installation repairing removing and disposal during which flammable refrigerant can possibly be...

Page 26: ...most critical point to warn of a potentially hazardous situation 2 Particular attention shall be paid to the following to ensure that by working on electrical components the casing is not altered in...

Page 27: ...by cutting or brazing The refrigerant charge shall be recovered into the correct recovery cylinders The system shall be flushed with OFN to render the unit safe This process may need to be repeated se...

Page 28: ...late system electrically c Before attempting the procedure ensure that Mechanical handling equipment is available if required for handling refrigerant cylinders All personal protective equipment is av...

Page 29: ...g or damage to the product in transit 4 If warranty service is required you should a contact Evo Industries Australia on 1300 859 933 or via our Contact page on our web site b provide a copy of your r...

Reviews: