24
•
PCL-726 Calibration
4.3.1 Unipolar output voltage calibration with –10V internal reference
voltage
1. Follow the description at 2.7 to set the jumper.
2. Connect the terminal board PCLD-9137
3. Run 726UTIL.EXE under DOS, press <F3> and then
<PgUp/PgDn> to set the output voltage from each D/A analog
output channel as +10V, measure these output voltages one by
one by using the digital multi-meter, adjust VR1-1, VR2-1, VR3-1,
VR4-1, VR5-1 and VR6-1 to ensure the actual output voltage from
each channel is +10V
4.3.2 Bipolar output voltage with –10V internal reference voltage
1. Follow the description at 2.7 to set the jumper.
2. Connect the terminal board PCLD-9137
3. Run 726UTIL.EXE under DOS, press <F3> and then
<PgUp/PgDn> to set the output voltage from each D/A analog
output channel as 0V, measure these output voltages one by one
by using the digital multi-meter, adjust VR1-2, VR2-2, VR3-2,
VR4-2, VR5-2 and VR6-2 to ensure the actual output voltage
from each channel is 0V
4.3.3 Unipolar voltage calibration with –5V internal reference voltage
1. Follow the description at 2.7 to set the jumper.
2. Connect the terminal board PCLD-9137
3. Run 726UTIL.EXE under DOS, press <F3> and then
<PgUp/PgDn> to set the output voltage from each of D/A analog
output channel is +5.00V. Measure these output voltages one by
one by using the digital multi-meter, adjust VR1-1, VR2-1, VR3-1,
VR4-1, VR5-1 and VR6-1 to ensure the actual output voltage
from each channel is +5.00V
4.3.4 Unipolar current calibration with –5V internal reference voltage
1. Follow the description at 2.7 to set the jumper.
2. Connect the terminal board PCLD-9137
3. Run 726UTIL.EXE under DOS, press <F3>, follow the current
Summary of Contents for PCL-726
Page 1: ...PCL 726 6 Channel D A Output Card ...
Page 4: ......
Page 6: ......
Page 13: ...Installation 7 2 3 PCL 726 s Layout Figure 2 1 PCL 726 s Layout ...
Page 20: ...14 Installation ...