Page 1: ...K Simplex Monobloc Bypass M BSP DE Installation Bedienungsanleitung Seite 2 WASSERENTHÄRTER SIMPLEX EN Installation Operating Guide Page 8 WATER SOFTENER SIMPLEX FR Guide d Installation Utilisation Page 14 ADOUCISSEUR D EAU SIMPLEX ...

Page 2: ...emperatur min max 4 C 39 F 40 C 104 F ANSCHLUSSE Einlass Auslass BSP Außengewinde Abfluss des Steuerventils Schlauchtülle 13 mm Überlauf vom Salzbehälter Schlauchtülle 13 mm D O D Delta Open Drain Abflussadapter Außendurchmesser 40 mm 1 57 36 mm 1 42 LEISTUNG Nenndurchfluss Betrieb Δp 1 bar 15 psi 25 ltr min 6 6 gpm Durchfluss Abfluss max 3 ltr min 0 8 gpm Austauschkapazität pro Betriebszyklus 150...

Page 3: ...nn des Betriebszyklus sind die Ionenaustauschharzkügelchen im Inneren des Geräts mit Natriumionen beladen Da das Ionenaustauscherharz bevorzugt Calcium und Magnesiumionen anzieht geben die Harzkügelchen wenn hartes Wasser durch das Gerät fließt ihre Natriumionen an das Wasser ab und ersetzen sie im Gegenzug durch Calcium und Magnesiumionen Dieser Ionenaustauschprozess wird fortgesetzt bis alle Nat...

Page 4: ...und den Überlauf des Salzbehälters Bei einer festen Verbindung der Schläuche mit dem Abwassersystem muss ein Luftspalt vorgesehen werden um Rückfluss zu verhindern laut EN1717 Verwenden Sie den mitgelieferte D O D Abflussadapter stellen Sie sicher dass er in einem Standrohr mit einer Länge von min 20 cm installiert ist Um eine einwandfreie Funktion des Geräts zu gewährleisten vermeiden Sie Einklem...

Page 5: ...deutscher Grad 17 8 ppm CaCO3 1 gpg grains pro Gallone 17 1 ppm CaCO3 2 Drehen Sie mit Hilfe eines Inbusschlüssels n 5 den Einlasshärte Regler auf den ppm Wert der der Härte des unbehandelten einströmenden Wassers entspricht VERSCHNEIDUNGSREGLER WICHTIGER HINWEIS Mit dem Verschneidungsregler kann die Resthärte des behandelten Wassers am Ausgang des Gerätes reguliert werden Einmal abgeregelt wird u...

Page 6: ...Gerät in Bypass Position stellen drehen Sie den Griff am Bypassventil im Uhrzeigersinn in die BYPASS Position Gerät in Betriebs Position stellen drehen Sie den Griff am Bypassventil gegen den Uhrzeigersinn in die OPEN Position SALZ NACHFÜLLEN WICHTIGER HINWEIS EINE AUSREICHENDE MENGE AN REGENERATIONSSALZ IM SALZBEHÄLTER IST FÜR DIE ORDNUNGSGEMÄßE FUNKTION DES GERÄTS VON WESENTLICHER BEDEUTUNG Wir ...

Page 7: ...Seite 7 DEUTSCH ...

Page 8: ...C 39 F 40 C 104 F CONNECTIONS Inlet outlet BSP male Drain from control valve hose barb 13 mm Overflow from brine cabinet hose barb 13 mm D O D Delta Open Drain adaptor outer diameter 40 mm 1 57 36 mm 1 42 PERFORMANCE Nominal service flow rate Δp 1 bar 15 psi 25 ltr min 6 6 gpm Drain flow rate max 3 ltr min 0 8 gpm Exchange capacity per service cycle 150 ppm x m3 2 300 grains Salt consumption per r...

Page 9: ...e the device are loaded with sodium ions because the ion exchange resin has a preference to attract calcium and magnesium ions the resin beads when hard water flows through the device release their sodium ions to the water and in return replace them by calcium and magnesium ions This ion exchange process continues until all sodium ions on the resin beads are replaced by calcium and or magnesium io...

Page 10: ...he drain of the control valve and the overflow of the brine cabinet to the sewerage system Always use separate hoses for the drain of the control valve and the overflow of the brine cabinet In case of a permanent connection of the hoses to the sewerage system an air gap must be provided to prevent any form of backflow required by European standard EN1717 Use the provided D O D adaptor make sure it...

Page 11: ...German degree 17 8 ppm CaCO3 1 gpg grains per gallon 17 1 ppm CaCO3 2 Using a hex key n 5 turn the inlet hardness regulator to the ppm value corresponding to the hardness of the untreated incoming water HARDNESS BLENDING REGULATOR IMPORTANT NOTICE The hardness blending regulator can be used to regulate the residual hardness of the treated water as it leaves the device Once set it blends untreated ...

Page 12: ...vice hydraulically from the piping To put the device in bypass position rotate the handle on the bypass valve clockwise to the BYPASS position To put the device in service position rotate the handle on the bypass valve counter clockwise to the OPEN position SALT REFILLING IMPORTANT NOTICE A SUFFICIENT AMOUNT OF REGENERATION SALT INSIDE THE BRINE CABINET IS ESSENTIAL FOR PROPER FUNCTIONING OF THE D...

Page 13: ...Page 13 ENGLISH ...

Page 14: ...rature de service min max 4 C 39 F 40 C 104 F RACCORDEMENTS Entrée Sortie BSP mâle Égout de la vanne de commande raccord cannelé 13 mm Trop plein du bac à sel raccord cannelé 13 mm D O D adaptateur d égout Delta Open Drain diamètre extérieur 40 mm 36 mm PERFORMANCE Débit de service nominal Δp 1 bar 15 psi 25 ltr min 6 6 gpm Débit à l égout max 3 ltr min 0 8 gpm Capacité d échange par cycle de serv...

Page 15: ... que la résine échangeuse d ions a une préférence pour attirer les ions calcium et magnésium les billes de résine lorsque l eau dure s écoule à travers l appareil lâchent leurs ions Sodium dans l eau et en échange les remplacent par des ions calcium et magnésium Ce processus d échange d ions se poursuit jusqu à ce que tous les ions sodium sur les billes de résine soient remplacés par des ions calc...

Page 16: ...sel En cas de raccordement permanent des tuyaux au réseau d évacuation une rupture de charge doit être prévue afin de prévenir toute forme de refoulement requis par la norme européenne EN1717 Utilisez l adaptateur d égout D O D fourni assurez vous qu il est installé dans un tube rigide vertical d au moins 20 cm de long Pour garantir le bon fonctionnement de l appareil évitez pincements nœuds et él...

Page 17: ...d 17 8 ppm CaCO3 1 gpg grains par gallon 17 1 ppm CaCO3 2 À l aide d une clé hexagonale n 5 tournez le régulateur de dureté entrante à la valeur ppm correspondante à la dureté de l eau entrante non traitée REGULATEUR DE DURETÉ RÉSIDUELLE NOTICE IMPORTANTE Le régulateur de dureté résiduelle peut être utilisé pour réguler la dureté résiduelle de l eau traitée lorsqu elle sort de l appareil Une fois ...

Page 18: ...osition bypass tournez la poignée de la vanne bypass en sens horaire jusqu à la position BYPASS Pour mettre l appareil en position service tournez la poignée de la vanne bypass en sens antihoraire jusqu à la position OPEN REMPLISSAGE DE SEL NOTICE IMPORTANTE UNE QUANTITÉ SUFFISANTE DE SEL DE RÉGÉNÉRATION À L INTÉRIEUR DU BAC À SEL EST ESSENTIELLE POUR LE BON FONCTIONNEMENT DE L APPAREIL Nous vous ...

Page 19: ...Page 19 FRANCAIS ...

Page 20: ...ABBILDUNGEN ILLUSTRATIONS Seite Page 20 1 2 a 2 b 2 c ...

Page 21: ...ABBILDUNGEN ILLUSTRATIONS Seite Page 21 3 4 5 a 5 b ...

Page 22: ...ABBILDUNGEN ILLUSTRATIONS Seite Page 22 6 a 6 b 6 c 6 d 7 ...