Page 12
6.1.1.
DO NOT connect any electrical appliances to the machine.
6.1.2.
Select required output voltage.
6.1.3.
Check the output on the Voltmeter is reading the correct voltage.
6.1.3.1.
Display will read output voltage depending on the selection either 115 VAC or
230 VAC
6.1.4.
Turn the main AC switch to the 'OFF' position.
6.1.5.
Insert the plug into the outlet you are about to use.
6.1.6.
Turn the main AC switch to the 'ON' position and turn the electrical appliance ‘ON’.
6.2.
Using DC outlet
6.2.1.
The DC outlet is an unregulated 12 VDC @
8.3 Amps.
6.2.2.
Charging instructions for the battery.
6.2.2.1.
Disconnect the battery leads.
6.2.2.2.
Open the battery filler caps.
6.2.2.3.
Check that the batteries are full to
the upper limit.
6.2.2.4.
Only use distilled water to fill up
battery.
6.2.2.5.
Measure the specific gravity (SG)
of the battery fluid (electrolyte) and
calculate the charging time in accordance with the table to the right.
6.2.2.6.
The specific gravity for a fully charged battery shall be between 1.255 and
1.275. You should check the SG every hour.
6.2.2.7.
If the battery requires charging connect the battery to the 12 V 8.33 Amp
charging outlet. Make sure you observe the correct polarity at the battery. Red to
positive and Black to negative.
Explosives gases are given off when charging a battery. ONLY charge in a
well-ventilated area, away from sparks and naked flames.
Exercise care when charging batteries to make sure that the battery does
not get overcharged or overheats.
%
Charged
Approximate
Voltage
Specific
Gravity
100%
13.2
1.255 – 1.275
75%
9.9
1.215 – 1.235
50%
6.6
1.180 – 1.200
25%
3.3
1.155 - 1.165
0%
0
1.110 - 1.130
Summary of Contents for EVO3100
Page 23: ...Page 23 NOTES ...