(2) MANUAL OVERRIDE
To keep the light on regardless of the motion, you can
override the Automatic Operation. By turning the wall
switch off and on within 2 seconds, the light will remain
on. Users can also set the motion sensor back to
Automatic Operation by turning off the wall switch for at
least 10 seconds and then turn it back on.
TROUBLE SHOOTING
Light does not turn on:
l
Confirm that you have made a correct “wiring
connection”.
l
Make sure that the bulb has not burned out.
Light remains on:
l
Make sure the wiring connection is correct.
l
If you set the motion sensor to Manual Override,
remember that you must turn the wall switch off
for at least 10 seconds before switch the motion
sensor on back to Automatic Operation.
l
Check if the TIME setting is correct.
SPECIFICATIONS
Power Requirement
AC 220 ~ 240V / 50Hz
Power Cord Requirement H05RN-F, 3G, 1.0mm²
Lighting Load
Max. 150W x 2 PAR38
Bulb
Detection Angle
Up to 180
°
at 20
°
C
Detection Distance
Up to 12M at 20
°
C
Swiveling Angle
Lamp Part: Horizontal 170°;
Sensor Part: Horizontal 40
°
,
Vertical 60
°
Mounting Height
Recommended 1.8 ~ 2.5M
(5.9 ~ 8.2 Ft) Wall Mount
Wall Switch Control
On / Off / Manual Override
Sensor Operation
Auto
Time Adjustment
5 ± 3 sec ~ 12 ± 3 min
Lux Adjustment
Approx. 0 ~ 1,000 Lux.
Operating Temperature
-20
°
C ~ +40
°
C
Warm Up Time
About 1 min
Protection Class
Class II
Protection Degree
IP44
Safety
CE, GS
INES62EVSPEF
6