background image

FIGURE 8

(6)   Strip approximately 6-8mm insulating part of the

wires from the power cord. Before connection,
ensure that the wall box gasket is firmly seated in
its original place.

(7) 

  Connect the BROWN wire (Live wire) to the terminal

block “L” mark. Connect the BLUE wire (Neutral wire)
to the terminal block “N” mark (FIGURE 9).

 

 FIGURE 9

 
(8)  Use the pressure block to fix the power cord by

fastening its two screws.

(9)  Place the wall plate to the wall box and secure it

with the two screws provided.

SETTING THE LIGHTING SYSTEM

(1)

 

TEST MODE

l

 

Turn the Lite control and the Time control anti-
clockwise to the edge – the TEST position (FIGURE
10).

FIGURE 10

l

 

Turn on the wall switch. The floodlight will turn on for
about 1 minute to warm up. Then it turns off. Walk
through the detection area. The floodlight turns on
when you move and turns off when you stop. Wait
for the floodlight to turn off before moving again to
test the sensor.

4

l

 

Adjust the motion sensor to cover the desired
detection area. For a smaller coverage area, point
the sensor down; for a larger coverage area, point
the sensor up.

(2) TIME ADJUSTMENT

The TIME adjustment controls how long the floodlight will
stay on after the motion has been detected.

Turn the TIME control knob clockwise to increase (up to
about 12 minutes) how long the floodlight stays on or
anti-clockwise to decrease (down to about 5 seconds)
the time delay (FIGURE 11).

FIGURE 11

(3) LITE ADJUSTMENT

The LITE adjustment determines at what light level the
lighting system will start operating when you set the
sensor to Automatic Operation.

Provisionally turn the LITE control knob to the edge
clockwise at the moon (dusk) position (FIGURE 12). In
this provisional setting mode, the motion sensor’s
remains inactive during daylight. At dusk when you find it
is the LUX level desired for operation, simply set the LITE
control knob to the position that the motion sensor
floodlight will become active as daylight declines.

FIGURE 12

OPERATION

By using the wall switch connected to your motion
sensor floodlight, you can easily select one of two modes
of operation: Automatic Operation and Manual Override.

(1) AUTOMATIC OPERATION

Turn on the wall switch. When the motion sensor detects
motion, the floodlight automatically turns on. The built-in
photocell sensor turns the motion sensor off and on
according to the light level set by the LITE Adjustment.

5

Summary of Contents for ES62

Page 1: ... avoid any rotation l The unit can be installed only horizontally FIGURE 1a not vertically FIGURE 1b HORIZONTAL VERTICAL FIGURE 1a 1b IMPORTANT Some local building codes may require installation of this product by a qualified electrician Check your local codes as they apply to your situation If the house wiring is of aluminum consult with an electrician about proper wiring methods Maintenance or r...

Page 2: ...er source FIGURE 4 This will help you operate this motion sensor floodlight with ease See OPERATION for further information Note Keep the bulb away from the wall at least 50mm FIGURE 5 2 FIGURE 5 WIRING INSTRUCTION 1 Switch off the power source or wall switch 2 Remove the wall box s back plate then unscrew two screws on the pressure block FIGURE 6 FIGURE 6 Note There is a UP mark shown on the inte...

Page 3: ...2 TIME ADJUSTMENT The TIME adjustment controls how long the floodlight will stay on after the motion has been detected Turn the TIME control knob clockwise to increase up to about 12 minutes how long the floodlight stays on or anti clockwise to decrease down to about 5 seconds the time delay FIGURE 11 FIGURE 11 3 LITE ADJUSTMENT The LITE adjustment determines at what light level the lighting syste...

Page 4: ...ride remember that you must turn the wall switch off for at least 10 seconds before switch the motion sensor on back to Automatic Operation l Check if the TIME setting is correct SPECIFICATIONS Power Requirement AC 220 240V 50Hz Power Cord Requirement H05RN F 3G 1 0mm Lighting Load Max 150W x 2 PAR38 Bulb Detection Angle Up to 180 at 20 C Detection Distance Up to 12M at 20 C Swiveling Angle Lamp P...