Eversol TL1500AS Operating Instructions Manual Download Page 4

4                                                                                                                  Operating  Instructions 

3 Operating 

3.1 Overview 

 

 

Object 

Description 

The inverter is working normally (Green LED) 

A fault happens (Red LED) 

The inverter is communicating with other device (Yellow LED) 

Function key 

LCD display 

 

3.2 LED display 

Eversol inverters are equipped with three LEDs including “green”, “red” and 
“yellow” which provide information about various operating status in the following 

ways.   

 

 

Summary of Contents for TL1500AS

Page 1: ...ructions and regulations 3 2 1 Intended use 3 2 2 Safety operating instructions 3 3 Operating 4 3 1 Overview 4 3 2 LED display 4 3 3 LCD display 6 3 4 Function key 8 3 4 1 Setting the Language 8 3 4 2...

Page 2: ...nergy inverters of the type Eversol TL 1500AS 1700GB UK version and 2000AS 2000GB UK version 1 2 Target group This documentation is intended for the operator of the system Info provided here mainly in...

Page 3: ...and regulations In addition opening of the inverter and any electrical installation repair or modification of the inverter may also only be performed by authorized skilled electrician 2 The Eversol m...

Page 4: ...ly Green LED B A fault happens Red LED C The inverter is communicating with other device Yellow LED D Function key E LCD display 3 2 LED display Eversol inverters are equipped with three LEDs includin...

Page 5: ...The yellow LED lights up during the inverter communicating with other devices including PMU and PC and goes out after the communication finished LEDs State Comment Green Normal The inverter is operat...

Page 6: ...information as follows Line 1 State information Current state information all possible content shows in the following table E today The energy generated today in kilo watt hours kWh E total The energy...

Page 7: ...e failure Utility Loss No Utility Island PV Over Voltage Input voltage too high Fan Lock Fan abnormal Over Temperature Temperature abnormal Consistent Fault Consistent failure occur for the first time...

Page 8: ...guages At the entry of SetLanguage press the key for approx 5 seconds you can enter the language menu Select the language which you require with the function key Keep this state without any operation...

Page 9: ...ection unplug the inputs from the PV generator and check the peripheral AC system 3 After the cause is cleared re plug the PV panel and AC connection and check PV Inverter status Grid Fault Fac Over R...

Page 10: ...the LCD switches off reconnect and check again 4 If the problems remain please call local service DC INJ High EEPROM R W Fail SCI Failure AC HCT Fault GFCI Failure If there is no display on the panel...

Page 11: ...the customer In addition the type label on the unit must be fully legible If these requirements are not fulfilled Eversolar New Energy reserves the right to deny warranty services Warranty claims are...

Page 12: ...ls Ensure that they are disposed of appropriately 7 Contact If you have technical problems about our product you can contact us via www gigabiz co uk Tel 08444 930099 Email info gigabiz co uk www ever...