2 Safety instructions and regulations 

2.1 Intended use 

The Eversol inverter converts the DC power generated by the photovoltaic (PV) 

modules into AC power and feed this into the power supply. Eversol inverters are 

built according to the safety rules. However, improper use may cause lethal hazard 

for the operator, third parties or the units and other property. Meanwhile, any other 

or additional and mobile use is prohibited. Alternative use, modifications to the 

Eversol or the operation of inverter not expressly recommended by Eversolar New 

Energy will invalidate the warranty claims. 

2.2 Safety operating instructions 

1.

 

The inverters must be installed by an authorized skilled electrician who is 

responsible for observing existing standards and regulations. In addition, 

opening of the inverter, and any electrical installation, repair or modification of 

the inverter may also only be performed by authorized skilled electrician. 

2.

 

The Eversol may only be operated with PV generators. Do not connect any 

other sources of energy to the Eversol. 

3.

 

Some part of the Eversol housing become hot during 

operation, and sometimes the temperature can reach 60 

 in normal operation. Don’t touch that part for danger 

of burn.   

4.

 

Don’t lay flammable and explosive materials close to the system.   

5.

 

Be sure that the system is out of the children’s reach. 

6.

 

Don’t put any things on the inverter. 

7.

 

Before cleaning, disconnect the system from the power grid by opening the AC 

breaker and open the DC switch on the PV generator, in order to exclude the 

danger of electric shocks. Don’t touch the inverter in five minutes. Use a soft, 

dry cloth to clean the system. Never use corrosive, solvent-containing or 

abrasive cleaners or polishes. 

 

Summary of Contents for TL1500AS

Page 1: ...ructions and regulations 3 2 1 Intended use 3 2 2 Safety operating instructions 3 3 Operating 4 3 1 Overview 4 3 2 LED display 4 3 3 LCD display 6 3 4 Function key 8 3 4 1 Setting the Language 8 3 4 2...

Page 2: ...nergy inverters of the type Eversol TL 1500AS 1700GB UK version and 2000AS 2000GB UK version 1 2 Target group This documentation is intended for the operator of the system Info provided here mainly in...

Page 3: ...and regulations In addition opening of the inverter and any electrical installation repair or modification of the inverter may also only be performed by authorized skilled electrician 2 The Eversol m...

Page 4: ...ly Green LED B A fault happens Red LED C The inverter is communicating with other device Yellow LED D Function key E LCD display 3 2 LED display Eversol inverters are equipped with three LEDs includin...

Page 5: ...The yellow LED lights up during the inverter communicating with other devices including PMU and PC and goes out after the communication finished LEDs State Comment Green Normal The inverter is operat...

Page 6: ...information as follows Line 1 State information Current state information all possible content shows in the following table E today The energy generated today in kilo watt hours kWh E total The energy...

Page 7: ...e failure Utility Loss No Utility Island PV Over Voltage Input voltage too high Fan Lock Fan abnormal Over Temperature Temperature abnormal Consistent Fault Consistent failure occur for the first time...

Page 8: ...guages At the entry of SetLanguage press the key for approx 5 seconds you can enter the language menu Select the language which you require with the function key Keep this state without any operation...

Page 9: ...ection unplug the inputs from the PV generator and check the peripheral AC system 3 After the cause is cleared re plug the PV panel and AC connection and check PV Inverter status Grid Fault Fac Over R...

Page 10: ...the LCD switches off reconnect and check again 4 If the problems remain please call local service DC INJ High EEPROM R W Fail SCI Failure AC HCT Fault GFCI Failure If there is no display on the panel...

Page 11: ...the customer In addition the type label on the unit must be fully legible If these requirements are not fulfilled Eversolar New Energy reserves the right to deny warranty services Warranty claims are...

Page 12: ...ls Ensure that they are disposed of appropriately 7 Contact If you have technical problems about our product you can contact us via www gigabiz co uk Tel 08444 930099 Email info gigabiz co uk www ever...

Reviews: