10 Operating Instructions
PV over Voltage
1.
Check the open PV voltage, see if it is greater
than or too close to 450VDC (for Eversol-TL
1500AS (1700GB UK version)) or 500VDC
(for Eversol-TL 2000AS (2000GB UK
version)).
2.
If PV voltage is less than 450VDC or
500VDC, and the problem still occurs, please
call local service.
Permanent
Fault
Consistent Fault
Disconnect PV (+) or PV (-) from the input, restart
the inverter.
Relay-Check Fail
1.
Disconnect ALL PV (+) or PV (-).
2.
Wait for a few seconds.
3.
After the LCD switches off, reconnect and
check again.
4.
If the problems remain please call local
service.
DC INJ High
EEPROM R/W
Fail
SCI Failure
AC HCT Fault
GFCI Failure
If there is no display on the panel, please check that the connection of the inverter
with PV generator and grid are correct. The safety information in this manual must
be fully observed in doing so.
If the PV voltage is higher than 150 V, but the inverter doesn’t work, please call
your local service.
During periods of little or no sunlight, the inverter may continuously start up and
shut down. This is due to insufficient power generated to operate the control circuits.
If the problems remain please call service.