DRAINAGE SYSTEMS
9.1 General
All water is drained by gravity to overboard thru-
hull fittings located in the hull above the water
line. It is important to check the drain system
frequently to ensure it is free flowing and that the
hoses on the thru-hull fittings are secure and not
leaking. Please review the drainage schematic
to become familiar with the location of the drain
thru-hull fittings.
9.2 Cockpit Sole Drains
Your Everglades has two scupper drains located in
the rear of the cockpit. A flap built into the scup
-
per drain fitting on 275/295 models reduces the
surge of seawater through the scupper and into
the cockpit while maneuvering or in rough water.
The scupper drain thru-hull fittings are in the trim
tab wells on the 325 Center Console
Water is channeled away from all hatches by a
gutter or drain rail system. The water then drains
overboard through the scupper drain system.
Ball valves in each scupper drain hose on 275/295
models can be closed to prevent seawater from
flowing into the cockpit through the scupper drain
system in an emergency. These valves should al-
ways be open during normal operating conditions.
Make sure to open and close each valve at least
once a month to keep the valves free and ensure
they will work if you need them.
9.3 Hardtop Drains
There is a hole drilled in the leg bases on Hardtop
frames to prevent water from being trapped within
the legs. Additional drain holes are drilled in the
tubing to drain other areas as required.
Always make sure the leg drain holes are clear
when the boat is laid up for the winter. Water
trapped inside the legs could freeze and cause
the legs to split.
Chapter 9:
9.4 Bilge Drainage
The bilge pumps are activated both manually by
switches in the helm switch panel and automati-
cally by float switches near each pump in the bilge.
The automatic float switches remain activated
when the battery switch is in the OFF position
and the batteries are connected. All bilge pumps
pump water out of thru-hull fittings located above
the waterline in the hull.
Typical Scupper Drains and Drain Rail
325 Center Console
Aft Bilge Pump and Automatic Switch
Summary of Contents for 2012 275 CC
Page 1: ...2012 Owner s Manual 275 cc 295 cc 325 cc ...
Page 2: ...2 Revision 1 10 24 2011 ...
Page 18: ...18 THIS PAGE WAS LEFT BLANK INTENTIONALLY ...
Page 24: ...24 THIS PAGE WAS LEFT BLANK INTENTIONALLY ...
Page 27: ...27 Operation ...
Page 40: ...40 THIS PAGE WAS LEFT BLANK INTENTIONALLY ...
Page 54: ...54 THIS PAGE WAS LEFT BLANK INTENTIONALLY ...
Page 76: ...76 THIS PAGE WAS LEFT BLANK INTENTIONALLY ...
Page 80: ...80 THIS PAGE WAS LEFT BLANK INTENTIONALLY ...
Page 110: ...110 THIS PAGE WAS LEFT BLANK INTENTIONALLY ...
Page 124: ...124 THIS PAGE WAS LEFT BLANK INTENTIONALLY ...
Page 125: ...125 SCHEMATICS Appendix A 275 295 Center Console Wiring Diagram ...
Page 126: ...Schematics 325 Center Console Wiring Diagram ...
Page 131: ...131 MAINTENANCE LOG Appendix C Hours Date Dealer Service Repairs ...
Page 132: ...132 Maintenance Schedule and Log MAINTENANCE LOG Hours Date Dealer Service Repairs ...
Page 133: ...133 Maintenance Schedule and Log MAINTENANCE LOG Hours Date Dealer Service Repairs ...
Page 134: ...134 Maintenance Schedule and Log MAINTENANCE LOG Hours Date Dealer Service Repairs ...
Page 135: ...135 Maintenance Schedule and Log MAINTENANCE LOG Hours Date Dealer Service Repairs ...
Page 136: ...136 Maintenance Schedule and Log MAINTENANCE LOG Hours Date Dealer Service Repairs ...
Page 137: ...137 Appendix D BOATING ACCIDENT REPORT ...
Page 138: ...138 Boating Accident Report ...
Page 139: ...139 Boating Accident Report ...
Page 140: ...140 THIS PAGE WAS LEFT BLANK INTENTIONALLY ...
Page 142: ...142 THIS PAGE WAS LEFT BLANK INTENTIONALLY ...
Page 147: ...CAUSE AND SOLUTION ...
Page 148: ...Everglades Boats 544 Air Park Road Edgewater Florida 32132 ...