![EverFocus PARAGON264x4 series Instruction Manual Download Page 65](http://html1.mh-extra.com/html/everfocus/paragon264x4-series/paragon264x4-series_instruction-manual_2443295065.webp)
58
HD Temperature:
Figure 4-13 Alarm & Event Menu – Event - HD Temperature
Log: Check box to record HDD temperature events in the log.
Buzzer: Check box to enable buzzer when hard drive’s temperature is over the “Temp. Warning Limit”.
Email Notify: Check box to enable email notification when HDD temperature is over the “Temp. Warning
Limit”. Email operation requires that valid email settings have been entered in the Network Setting/Email
setup screen.
Network Alarm: Check box to send out a network alarm to client PC. (requires PowerCon software and
setting up Alarm Server in Network Setup menu)
Stop Recording: Check box to stop recording when HD’s temperature is over the “Temp. Warning Limit”.
Temp. Warning Limit: Sets the trigger temperature for HD Temperature event actions. Choose between
55
C /131
F or 85
C /185
F.
Alarm Output: This will transmit a signal through the alarm output. It can be set to either “NONE” (not
active), “1”(active), “2”(active), “3”(active) or “4” (active).
Output Type: Output action will be Transparent and cannot be changed (alarm output remains as long as
the alarm condition is active).