59
HD Off:
Figure 5-16 Alarm & Event Menu – Event - HD Off
Buzzer:
Check box to enable buzzer when hard drive is off.
Email Notify:
Check box to enable email notification when HD is off.
Network Alarm:
Check box to send out a network alarm to client PC. (requires PowerCon software and
setting up Alarm Server in Network Setup menu)
Alarm Output:
Select from the dropdown menu whether or not an alarm signal shall be transmitted through
one of the alarm outputs to another device. Choose either “
NONE
” (disabled) or “
1
”, “
2
”, “
3
”, or “
4
”
(transmission through alarm output 1~4).
Output Type:
Output action when alarm is triggered.
Timeout: Alarm output remains switched for the set duration.
Permanent: Alarm remains switched until user presses the “Enter” key on front panel.
Transparent: Alarm output remains switched as long as there is an event.
Trans+Timeout: Alarm output remains switched until event ends and afterwards for the set duration.
Timeout Duration:
The amount of time the buzzer sounds when the HD is off. Duration selectable from 1
to 150
seconds.