![Eventide DIR911 Quick Reference Manual Download Page 23](http://html.mh-extra.com/html/eventide/dir911/dir911_quick-reference-manual_2442481023.webp)
©2000 Eventide Inc.
DIR911 Instant Recall Recorder
17
CHANGING SECURITY LEVEL Screen
-
Change the security level
There are two levels of security available in the DIR911: HIGH and LOW. If the DIR911
is set to low security, there is no password protection. If it is set to high security, you can
only edit the DIR911 configuration information by entering your password. High security
is most useful when only one person (e.g., a supervisor) should have access to the
DIR911 configuration and operators are not permitted to change any settings. High
security is the factory default setting.
CONFIG 3 Screen
-
Configure Serial Input/Output, ANI and ALI configuration, field
firmware upgrade, select Traffic (light or heavy), and Autorestore time.
Press “SERIAL I/O” and jump into the configuration screen. Press “TRAFFIC” to select
LIGHT or HEAVY traffic(default is LIGHT). Press AUTORESTORE to change timing on
Autorestore feature (default is 0.25 seconds).. Press “DONE” when DIR911
configuration is complete.
CONFIGURE IO Screen
Press “CONFIG” to set up the serial IO communication rates for all four serial ports.
“MORE” leads to the ANI/ALI, field upgrade menu and “DONE” leaves the IO
configuration screens.
PORT CONFIG Screen
-
Configure Serial Input/Output Port
Current Security Level: HIGH SECURITY
CHANGE DONE
DIR911 System Configuration
SERIAL I/O TRAFFIC AUTORESTORE DONE
Configure IO port, Serial data info
CONFIG MORE DONE
External Time Sync IO Port (RS-485)
Rate:19200 Parity:None Data:8 Stop:1
Port A Out+ P8 Out- P9 In+ P6 In- P7
PORT CURSOR CHANGE DONE