No connection
ALARM
user interface-control module communication alarm
solutions:
-
check user interface-control module control module
main consequences:
-
if the alarm occurs when the device is on, a cooking cycle cannot be started
-
if the alarm occurs during an cooking cycle, no consequence
Temperature
ALARM
maximum temperature alarm
solutions:
-
check the temperature detected by the environment probe; see parameters A0, A1 and A3
main consequences:
-
no consequence
Board
temperature
alarm
ALARM
Use temperature alarm.
solutions:
-
check the use temperature of the control module; see parameter A4
main consequences:
-
if the alarm occurs when the device is on, a cooking cycle cannot be started
-
if the alarm occurs during an cooking cycle, the cycle will be interrupted
-
the vent will be open, the technical compartment fan will be on and the remaining outputs will
be off
door micro switch input alarm
solutions:
-
check the causes of the activation of the input; see parameter i0
main consequences:
-
if the alarm occurs during a cooking cycle, the temperature regulation output, the fan and the
steam injection output will be switched off and the vent will be open
Circuit breaker
protection ALARM
fan circuit breaker protection input alarm
solutions:
-
check the causes of the activation of the input; see parameters i1 and i2
main consequences:
-
if the alarm occurs during a cooking cycle, the temperature regulation output and the fan will be
switched off
Peak absor.
ALARM
electric absorption input alarm
solutions:
-
check the causes of the activation of the input; see parameter i4
main consequences:
-
if the alarm occurs during an cooking cycle, the outputs will be off
When the problem that caused the error disappears, the device is restored to normal operation.