menu SET CLOCK 

 

Use this function to set current time and date. The control board is equipped with a lithium battery guaranteeing the time clock 3/5 year-long autonomy. Set the 

current date by pressing OK and the respective arrows to increase or decrease the selected values. 

 

menu CHRONO  

Submenu – ENABLE CHRONO: 

The menu shown on the "ENABLE CHRONO" display allows overall enabling and disabling of all the chronothermostat functions. To enable, press the P1 

button. Press P3 button to confirm. 

 

Submenu – DAILY CHRONO:

 

Once the "DAILY CHRONO" menu has been selected, the daily chrono is enabled using the P1 and P2 buttons. With the P4 button, the possible items can 

be scrolled through, including: switch-on time, switch-off time, set stove heat output, room temperature. It is possible to set two operating ranges. The OFF 

setting tells the clock to ignore the command. To change use the keys P1 and P2 while to confirm press P3. 

 

Submenu – WEEKLY CHRONO: 

The "WEEKLY CHRONO" menu allows enabling/disabling and setting of the weekly chronothermostat functions. The weekly programming function features 

4 independent programmes. Moreover, if the time is set to OFF, the time clock ignores the corresponding control. To change use the keys P1 and P2 while to 

confirm press P3. 

In each program you will find: Switch-on time, Switch-off time, Set stove heat output, Room temperature, Days of the week for which the programme is to be 

active. Monday is 1 and Sunday is 7. 

 

Submenu – CHRONO WEEK-END 

It is used to enable/disable and to set the chronothermostat functions on weekends (days 6 and 7, i.e. Saturday and Sunday). To enable, press the P1 and 

P2 buttons. Setting the times 

Start 1 

and

 Stop 1 

sets the operating period for 

Saturday

, while

 Start 2 

and 

Stop 2 

are used to set the stove operation for 

Sunday. 

In each program you will find: Switch-on time, Switch-off time, Set stove heat output, Room temperature. 

 

menu SELECT LANGUAGE  

Use this command to select one of the languages available. To move to the next language press P1 (increase) to go back, press P2 (decrease) and to confirm 

press P4. 

 

menu MODE BUZZER  

It is used to enable or disable the buzzer board. 

 

menu INITIAL LOAD  

This function is only available when the stove is OFF and is used to load the auger when the stove is started for the first time when the pellet hopper is empty. After 

selecting the menu, press P1. The exhaust blower switches on at the maximum speed and the auger tube (auger tube LED on) starts working. They will switch off 

once the period of time indicated on the display has elapsed or after pressing the P3 button. 

 

menu STOVE STATUS  

Enter the STOVE STATUS menu, after pressing the P4 button, the display scrolls the status of a number of variables during operation of the stove at work. 

 

menu TECHNICAL  

This menu item is reserved for the stove installer. 

 

menu STAND-BY 

 

In this menu it is possible to activate or deactivate the automatic stand-by of the stove. When selected, if the conditions have all been met, the stove will enter 

MODULAT – OK STDBY. This state lasts for 10 minutes. Once this time has elapsed, the stove will switch off and then switch on again when required. 

 

USER FUNCTIONS 

Standard functioning of a control board properly installed on an air stove is described below with reference to the functions available to users. 

 

Stove ignition 

Hold P3 button down for a few seconds to switch on the stove. Successful ignition is indicated on the display with the word "START". During this phase, the stove 

goes into pre-heating status; both the glow plug (as indicated by the corresponding glow plug LED) and the exhaust blower switch on. 

Any problem detected during the switching-on phase is indicated on the display and the stove goes into alarm status. 

 

Loading with Pellets 

After approximately 1 minute the pellet loading phase begins and the message "LOAD PELLETS" appears on the display. During the initial phase, the auger tube 

loads the pellets into the fire pit for a fixed time. In the second phase the auger tube turns off, while the speed of the fumes and the glow plug remain in the previous 

state. If ignition does not occur after this phase, the auger tube is switched on again and the glow plug remains on. 

 

Fire present 

Once fume temperature has reached and exceeded a pre-set threshold, the stove goes into the ignition mode and the message “FLAME LIGHT” appears on the 

display. The speed of the fumes is fixed, the auger tube turns on for a fixed time and the glow plug is turned off. Any problem during this phase will cause the 

control board to stop and the stove to go into error state. 

 

Stove operational 

After the temperature of the fumes has reached and exceeded a given value and has maintained it for at least a predetermined time, the stove goes into work 

mode which is the normal working mode. The upper display shows the time and the room temperature and the lower one the set power and the power in which 

the stove is found. The heat output can be set by pressing the P2 key and the room temperature can be set by pressing the P1 button. If the fume temperature 

reaches a certain set threshold, the air exchanger fan turns on. After this phase, the stove cleans the fire pit. The word "CLEANING FIRE-POT" scrolls on the 

display, the auger is on and the fume fan is on. Once the set period of time has elapsed, the stove goes back to the working mode. 

 

 

 

 

 

 

 

 

 

 

14

Summary of Contents for Cesare

Page 1: ...INSTRUCTION MANUAL STORAGE STOVES COSTANZA EN...

Page 2: ...facilitate stove s ignition 6 Should any anomaly concerning the flame be detected or however in any other case NEVER SWITCH OFF the stove by disconnecting it from the mains Use the relevant button Dis...

Page 3: ...STALLATION WARNINGS p 8 07 INSTALLATION p 10 07 1 PROCEDURE FOR CORRECT PRODUCT INSTALLATION p 10 07 2 ELECTRICAL CONNECTIONS p 12 07 3 EXTERNAL THERMOSTAT p 12 07 4 IGNITION p 12 08 PRODUCT USE p 12...

Page 4: ...technician Should the power supply cable be damaged it can be replaced only by the manufacturer or by its technical assistance service or by a similarly qualified person Do not place any object on th...

Page 5: ...he appliance will be automatically switched off It may take two separate ignitions to resume operation at ideal working conditions since the Auger tube is very long CAUTION If the stove is not properl...

Page 6: ...uisiti minimi del tiraggio del camino Pa 12 11 Flue gas temperature Fume temperature C 156 5 83 6 Flue gas temperature at flue spigot or socket Temperatura uscita fumi C 167 3 76 9 Flue gas mass flow...

Page 7: ...the flue pipe must be carried out in a workmanlike manner and according to European UNI 10683 and national regulations local regulations and the technical specifications and warnings contained in this...

Page 8: ...n be no bottlenecks No constrictions Use 10cm thick insulating thimbles if pipe vent passes through floors The flue pipe must be insulated along its entire length The insulation will make it possible...

Page 9: ...f a flue pipe rain fog snow altitude but the most important is the wind which can cause negative thermal pressure as well as dynamic negative pressure The wind action varies depending on whether it is...

Page 10: ...ENCY OF THE STOVE ENSURE THE FOLLOWING TYPES OF INSTALLATION BEFORE CONNECTION TO THE FLUE PIPE INSTALL THE PRODUCT WITH AT LEAST ONE T AND 1 METERS OF PIPE CERTIFIED ACCORDING TO EN 1856 2 06 INSTALL...

Page 11: ...d therefore there must not be any open flame apparatus in the same room with the exception of type C boilers airtight Make sure that the stove can draw the necessary quantity of combustion air this mu...

Page 12: ...hazard such as sheds garages storerooms for combustible materials etc These air intakes must be created in such a way that they cannot be obstructed neither from the inside nor from the outside and m...

Page 13: ...distribution of the material shake and wiggle the machine during the filling phase to fill every single gap There are 8 sandbags at your disposal Correct filling guarantees the use of all the bags sup...

Page 14: ...ean Do not use pellets of poor quality The use of substandard pellets can prevent the stove from reaching its maximum yield due to poor combustion and degradation of the stove itself Check that the do...

Page 15: ...utton to access the menu It includes several items and levels to access settings and control board programming USER MENU The table below briefly describes the menu structure focusing in particular on...

Page 16: ...n menu STOVE STATUS Enter the STOVE STATUS menu after pressing the P4 button the display scrolls the status of a number of variables during operation of the stove at work menu TECHNICAL This menu item...

Page 17: ...t value Set temperature value the stove will go back to the Work mode and to the previously set heat output Set heat output If there is an external thermostat and the room temperature has been set to...

Page 18: ...larm status can be reset by pressing the P3 button Safety thermostat In the event that the general safety thermostat detects a water temperature above the threshold the same intervenes to disconnect t...

Page 19: ...09 CONNECTIONS 17...

Page 20: ...use a dry cloth to clean the stove Do not use abrasive material or products that could corrode or bleach surfaces At the end of the season with the last ignition the pellet remaining in the auger must...

Page 21: ...E RESTARTS IN WORKING MODE FIRE PIT CLEANING WARNING APPEARS AFTER 8 HOURS OF STOVE OPERATION 4 5 KW MODELS ONLY 8 HOURS ARE CUMULATIVE TO CLEAR THE WARNING PRESS ALL 3 BUTTONS ON THE DISPLAY FOR 4 5...

Page 22: ...THE FIRE DOOR IS CLOSED CORRECTLY CALL TECHNICAL SUPPORT THERM DOOR SAFETY ALARM THERMAL SAFETY THERMOSTAT OR FIRE DOOR OPEN CLOSED INCORRECTLY LET THE STOVE COOL RE ARM THE MANUAL THERMOSTAT AT THE R...

Page 23: ...tenance ____________ ____________ Technical Assistance Centre stamp Date 2nd maintenance ____________ ____________ Technical Assistance Centre stamp Date 3rd maintenance ____________ ____________ Tech...

Page 24: ...ion needed to correctly use operate and perform maintenance on the appliance CUSTOMER Signature DEALER INSTALLER Signature Copy of the dealer or installer CERTIFICATE OF INSTALLATION AND TESTING CUSTO...

Page 25: ...cs of the coating materials are excluded from the warranty the grains of the stones that are the main characteristic and that guarantee their uniqueness any small cracks or cracks that could be highli...

Page 26: ...sponsibility for such disposal is to be borne by the owner and to not incur sanctions or adverse effects on the environment and health we recommend you contact the local administration the local waste...

Page 27: ...tion totale ou partielle sans autorisation expresse de Eva Stampaggi S r l est interdite Die angegebenen Daten und Eigenschaften binden das Unternehmen Eva Stampaggi S r l nicht das sich das Recht vor...

Reviews: