04. MINIMUM INSTALLATION REQUIREMENTS 

 

 

INTRODUCTION: 

 

 

INSTALLATION WITH WALL FUME OUTLET IS PROHIBITED.  INSTEAD THE FUME OUTLET MUST BE ROOF-TYPE AS PROVIDED FOR BY NATIONAL 

REGULATIONS. 

 

Eva Stampaggi S.r.l. assumes no responsibility for damage to persons and/or property caused by non-compliance with the point highlighted above 

for products installed in a non-compliant manner. 

Install the stove according to the regulations in force in the country of use. 

 

 

In Italy, for example, this refers to UNI 10683: 2012, which refers to 4 areas: 

 

a. preliminary activities -

 are under the jurisdiction and are the responsibility of the reseller/installer at the time of the pre-installation inspection. Preliminary 

procedures include: 

  installation site suitability verification; 

  fume evacuation system suitability verification; 

  external air inlet suitability verification. 

At this stage, the product needs to be checked in order that it can be safely operated and that the relevant technical specifications are met. 

The safety conditions must be assessed with a preventive inspection. 

Stoves and fireplaces are heating systems and must be installed safely

 

and comply with the manufacturer's instructions!

 

 

b. installation -

 under the responsibility of the installer. In this phase the 

installation 

of the product and the smoke exhaustion system are considered as well as 

the handling of topics such as: 

 

safety distance

 from combustible materials; 

 

chimney flue construction

, smoke ducts, intubated systems and chimney cowls. 

 

c. issuance of supplementary documentation

 - the responsibility of the installer. 

The release of technical documentation must include: 

  manual of use and maintenance of the appliance and of the components of the system (e.g smoke ducts, chimney flue, etc.); 

  Photocopy or photograph of the chimney flue plate; 

  system manual: (if applicable); 

 

Declaration of Conformity in relation to Ministerial Decree 37/08

 

d. control and maintenance

 - the responsibility of the maintenance technician who must oversee protection and maintenance of the product during its operation 

over time.

 

The operator responsible for checking and maintaining the systems for winter and summer climate control carries out tasks in 

a workmanlike manner

 

and in observance of applicable regulations. The operator, at the end of these operations, must draw up and sign a technical inspection report in accordance with 

the models provided by the provisions of this decree and the implementing rules, in relation to the type and capacity of the system, to be issued to the person who 

signs a copy thereby confirming receipt and reading thereof".

 

 

In addition to what is specifically provided for in the following paragraphs of this Instruction Manual, the Purchaser must comply with the following minimum 

installation requirements: 

a)  Do not invert or place the stove horizontally on one side; 

b)  The power of the stove must be adapted to the size of the room where it is to be installed and the room must be ventilated from the outside; 

c)  The assembly of the flue pipe must be carried out in a workmanlike manner and according to European (UNI 10683) and national regulations, local 

regulations and the technical specifications and warnings contained in this Instruction Manual; 

d)  The smoke outlet must be connected to the flue pipe by means of telescopic fittings; 

e)  The diameter of the flue must be less than 150 mm. 

f)  The connection to the flue pipe must be made with an inclination connection of less than 45°; 

g)  The flue pipe must be suitably insulated; 

h)  The minimum length of the horizontal section must be greater than 2 metres; 

i) 

The minimum slope of the horizontal section must be 5% 

j) 

The chimney and/or flue pipe must be waterproofed; 

k)  The flue shall not have more than two changes of direction; 

l) 

The flue gas must be discharged directly into the flue pipe; 

m)  The flue gas duct must have a length of less than 6.0 m before the flue, with a maximum horizontal section of 3.0 m; 

n)  The flue and flue duct must not narrow in width from the initial diameter for its entire length. The initial diameter shall be that of the exhaust outlet of the 

stove body; 

o)  The minimum value of the ventilation duct opening must be 80 cm²; 

p)  The distance of the flammable walls must be respected, as prescribed on the “stove data plate”; 

q)  The fire pit must be cleaned before each ignition of the stove. 

The Buyer must not make any structural changes to the stove and must not make any operating changes to the electrical board. 

Installation and connection must be carried out by the Purchaser and by qualified technical personnel, in compliance with European (UNI 10683) and national 

regulations, local regulations and assembly instructions contained in this Instruction Manual. 

Eva Stampaggi S.r.l. assumes no criminal and/or civil liability, direct and/or indirect, for damage to persons or property resulting from non-compliance with the 

aforementioned provisions of law, assembly instructions, warnings and general safety rules indicated in this Instruction Manual. 

Failure to comply with the installation requirements and/or tampering with the stove may result in: inadequate power and/or abnormal product behaviour, poor flue 

gas draught, clogging of the fire pit, slow combustion, tank fire, overheating and fire hazard of the stove, fire hazard of the flue gas duct, lack of oxygen in the 

environment where the stove is located. 

Eva Stampaggi S.r.l. assumes no criminal and/or civil liability, direct and/or indirect for the malfunction of the stove and for damage to persons or property caused 

by non-compliance with the requirements for installation of the stove and/or tampering with it. 

The Buyer must request and retain the certification of compliance of the installation, and the connection of the stove, with the provisions of law. In the absence of 

such certification Eva Stampaggi S.r.l. assumes no criminal and/or civil liability, direct and/or indirect for the malfunction of the stove and for damage caused to 

persons or property, resulting from the use of the product. 

 

Warning: in the event of a power failure or electrical blackout, the fire pit must be emptied before repeating the operation. Failure to follow this 

procedure may cause the door glass to break.

 

 

 

 

 

 

 

 

 

 

 

5

Summary of Contents for Cesare

Page 1: ...INSTRUCTION MANUAL STORAGE STOVES COSTANZA EN...

Page 2: ...facilitate stove s ignition 6 Should any anomaly concerning the flame be detected or however in any other case NEVER SWITCH OFF the stove by disconnecting it from the mains Use the relevant button Dis...

Page 3: ...STALLATION WARNINGS p 8 07 INSTALLATION p 10 07 1 PROCEDURE FOR CORRECT PRODUCT INSTALLATION p 10 07 2 ELECTRICAL CONNECTIONS p 12 07 3 EXTERNAL THERMOSTAT p 12 07 4 IGNITION p 12 08 PRODUCT USE p 12...

Page 4: ...technician Should the power supply cable be damaged it can be replaced only by the manufacturer or by its technical assistance service or by a similarly qualified person Do not place any object on th...

Page 5: ...he appliance will be automatically switched off It may take two separate ignitions to resume operation at ideal working conditions since the Auger tube is very long CAUTION If the stove is not properl...

Page 6: ...uisiti minimi del tiraggio del camino Pa 12 11 Flue gas temperature Fume temperature C 156 5 83 6 Flue gas temperature at flue spigot or socket Temperatura uscita fumi C 167 3 76 9 Flue gas mass flow...

Page 7: ...the flue pipe must be carried out in a workmanlike manner and according to European UNI 10683 and national regulations local regulations and the technical specifications and warnings contained in this...

Page 8: ...n be no bottlenecks No constrictions Use 10cm thick insulating thimbles if pipe vent passes through floors The flue pipe must be insulated along its entire length The insulation will make it possible...

Page 9: ...f a flue pipe rain fog snow altitude but the most important is the wind which can cause negative thermal pressure as well as dynamic negative pressure The wind action varies depending on whether it is...

Page 10: ...ENCY OF THE STOVE ENSURE THE FOLLOWING TYPES OF INSTALLATION BEFORE CONNECTION TO THE FLUE PIPE INSTALL THE PRODUCT WITH AT LEAST ONE T AND 1 METERS OF PIPE CERTIFIED ACCORDING TO EN 1856 2 06 INSTALL...

Page 11: ...d therefore there must not be any open flame apparatus in the same room with the exception of type C boilers airtight Make sure that the stove can draw the necessary quantity of combustion air this mu...

Page 12: ...hazard such as sheds garages storerooms for combustible materials etc These air intakes must be created in such a way that they cannot be obstructed neither from the inside nor from the outside and m...

Page 13: ...distribution of the material shake and wiggle the machine during the filling phase to fill every single gap There are 8 sandbags at your disposal Correct filling guarantees the use of all the bags sup...

Page 14: ...ean Do not use pellets of poor quality The use of substandard pellets can prevent the stove from reaching its maximum yield due to poor combustion and degradation of the stove itself Check that the do...

Page 15: ...utton to access the menu It includes several items and levels to access settings and control board programming USER MENU The table below briefly describes the menu structure focusing in particular on...

Page 16: ...n menu STOVE STATUS Enter the STOVE STATUS menu after pressing the P4 button the display scrolls the status of a number of variables during operation of the stove at work menu TECHNICAL This menu item...

Page 17: ...t value Set temperature value the stove will go back to the Work mode and to the previously set heat output Set heat output If there is an external thermostat and the room temperature has been set to...

Page 18: ...larm status can be reset by pressing the P3 button Safety thermostat In the event that the general safety thermostat detects a water temperature above the threshold the same intervenes to disconnect t...

Page 19: ...09 CONNECTIONS 17...

Page 20: ...use a dry cloth to clean the stove Do not use abrasive material or products that could corrode or bleach surfaces At the end of the season with the last ignition the pellet remaining in the auger must...

Page 21: ...E RESTARTS IN WORKING MODE FIRE PIT CLEANING WARNING APPEARS AFTER 8 HOURS OF STOVE OPERATION 4 5 KW MODELS ONLY 8 HOURS ARE CUMULATIVE TO CLEAR THE WARNING PRESS ALL 3 BUTTONS ON THE DISPLAY FOR 4 5...

Page 22: ...THE FIRE DOOR IS CLOSED CORRECTLY CALL TECHNICAL SUPPORT THERM DOOR SAFETY ALARM THERMAL SAFETY THERMOSTAT OR FIRE DOOR OPEN CLOSED INCORRECTLY LET THE STOVE COOL RE ARM THE MANUAL THERMOSTAT AT THE R...

Page 23: ...tenance ____________ ____________ Technical Assistance Centre stamp Date 2nd maintenance ____________ ____________ Technical Assistance Centre stamp Date 3rd maintenance ____________ ____________ Tech...

Page 24: ...ion needed to correctly use operate and perform maintenance on the appliance CUSTOMER Signature DEALER INSTALLER Signature Copy of the dealer or installer CERTIFICATE OF INSTALLATION AND TESTING CUSTO...

Page 25: ...cs of the coating materials are excluded from the warranty the grains of the stones that are the main characteristic and that guarantee their uniqueness any small cracks or cracks that could be highli...

Page 26: ...sponsibility for such disposal is to be borne by the owner and to not incur sanctions or adverse effects on the environment and health we recommend you contact the local administration the local waste...

Page 27: ...tion totale ou partielle sans autorisation expresse de Eva Stampaggi S r l est interdite Die angegebenen Daten und Eigenschaften binden das Unternehmen Eva Stampaggi S r l nicht das sich das Recht vor...

Reviews: