Commissioning
8.2
Commissioning in steps
Step
Action
Remark
1
Before switching on
Check the wirung, especially:
Filterpolarity, supply
motor wiring, motor polarity
resolver wiring, polarity (or other feedback systems)
2
with critical mechanical parts: remove motor shaft from
application
avoid danger
3
Connect PC by RS232 link to the drive service port
COM1 and start EASYRIDER
4
Set up state
NOT ACTIVE (X10.22 against X10.9)
Power ON
7-Segment-display
5
Switch on control voltage Us (DC 24V)
EASYRIDER communicates
(see diagnosis F9)
7-Segment-display
6
Are parameters already evaluated ?
yes:
load parameter file
xxx.ASD.
Store parameters in the drive.
If existent: load BIAS-file
xxx.EEUROTHERM and
store it in the drive.
proceed with
10 or 15
(experts)
no:
continue with
7
7
Menue Comissioning:
Select the used motor from the EASYRIDER- Library
Adjust max. current to nominal motor current or smaller
reduced torque
8
When leaving that menue:
Tuning-parameters for current loop will be calcualated
and offered to the user.
Normally, these values give dynamic servo motion.
confirm acceptance of offered
parameters
9
store data power-fail-save in the drive (F7)
10
Menue: Tuning speed loop
Summary of Contents for 635
Page 63: ...Product manual Model 635 DER u 635 K DER 07 01 05 06 E V1002 doc 63 10 Block circuit diagram ...
Page 72: ...72 Product manual Model 635 DER u 635 K DER 07 01 05 06 E V1002 doc 14 Certificates ...
Page 73: ...Product manual Model 635 DER u 635 K DER 07 01 05 06 E V1002 doc 73 Certificates ...
Page 74: ...74 Product manual Model 635 DER u 635 K DER 07 01 05 06 E V1002 doc Certificates ...
Page 75: ...Product manual Model 635 DER u 635 K DER 07 01 05 06 E V1002 doc 75 Certificates ...
Page 77: ...Product manual Model 635 DER u 635 K DER 07 01 05 06 E V1002 doc 77 16 Notes ...