background image

SI S

12

EN

cod. 3541A750  -  05/2011  (Rev. 00)

5. TECHNICAL DATA AND CHARACTERISTICS

Table. 7 - Key of figures cap. 5

5.1 General view and main components

fig. 13 - General view

5.2 Plumbing diagrams

fig. 14 - Water circuit

5.3 Technical data table

5

Sealed chamber

28

Fume manifold

7

Gas inlet

29

Fume outlet manifold

8

Domestic hot water outlet

38

Flowswitch

9

Cold water inlet

44

Gas valve

16

Fan

73

Antifreeze thermostat (not supplied)

19

Combustion chamber

81

Ignition and detection electrode

20

Burner assembly

187

Fume baffle

21

Main nozzle

288

Antifreeze kit (optional) code 013009X0

22

Burner

R1 - R2 - R3 - R4

 Electric heaters

27

Copper exchanger

344

Double sensor ( Heating)

44

81

19

27

16

5

28

344

20

21

22

29

38

187

9

7

8

Data

Unit

SI 11 S

SI 14 S

SI 17 S

Max. heating capacity

kW

21.7

26.9

32.9

(Q)

Min. heating capacity

kW

8.3

10.3

12.6

(Q)

Max. heat output

kW

19.2

23.9

29.2

Min. heat output

kW

7.1

8.8

10.7

Pmax efficiency

%

88.5

88.7

88.9

Burner nozzles G20

no.x Ø

10 x 1.25

12 x 1.25

14 x 1.25

Gas supply pressure G20

mbar

20.0

20.0

20.0

Max. gas pressure at burner

mbar

13.0

14.0

15.0

Min. gas pressure at burner

mbar

2.0

2.0

2.0

Max. gas delivery G20

m

3

/h

2.30

2.85

3.48

Min. gas delivery G20

m

3

/h

0.88

1.10

1.33

Burner nozzles G31

no.x Ø

10 x 0.77

12 x 0.77

14 x 0.77

Gas supply pressure G31

mbar

37

37

37

Max. gas pressure at burner

mbar

35.0

35.0

35.0

Min. gas pressure at burner

mbar

5.0

5.0

5.0

Max. gas delivery G31

kg/h

1.70

2.11

2.58

Min. gas delivery G31

kg/h

0.65

0.80

0.99

Max. working pressure

bar

10

10

10

(PMS)

Min. working pressure

bar

0.20

0.20

0.20

DHW flowrate 

'

t 25°C

l/min

11.0

13.7

16.8

DHW flowrate 

'

t 50°C

l/min

5.5

6.9

8.4

(D)

Protection rating

IP

X5D

X5D

X5D

Power supply voltage

V/Hz

230V

230V

230V

Electrical power input

W

40

40

55

Empty weight

kg

13

14

17

Type of unit

C

12

-C

22

-C

32

-C

42

-C

52

-C

62

-C

72

-C

82

-B

22

PIN CE

0461CL0983

8

9

38

344

Summary of Contents for SI 11 S

Page 1: ... 50 50 27 C B D E A 11 F 14 F 17 F A mm 295 335 375 C D B E mm 210 250 290 Modello IT ISTRUZIONE PER L USO L INSTALLAZIONE E LA MANUTENZIONE EN INSTRUCTIONS FOR USE INSTALLATION AND MAINTENANCE FR INSTRUCTIONS D UTILISATION D INSTALLATION ET D ENTRETIEN ...

Page 2: ...e anomalia combustione 10 Connessione Service Tool Indicazione durante il funzionamento Durante la richiesta sanitario generata dal prelievo d acqua calda sanitaria il display part 5 fig 1 visualizza l attuale temperatura d uscita dell acqua calda sanitaria Anomalia In caso di anomalia vedi cap 4 4 il display part 5 fig 1 visualizza il codice di guasto e durante i tempi di attesa di sicurezza le s...

Page 3: ...omologato per il funzionamento con tutte le configurazioni ca mini Cny riportate nella targhetta dati tecnici È possibile tuttavia che alcune configura zioni siano espressamente limitate o non consentite da leggi norme o regolamenti locali Prima di procedere con l installazione verificare e rispettare scrupolosamente le prescri zioni in oggetto Rispettare inoltre le disposizioni inerenti il posizi...

Page 4: ...ontemporaneamente i tasti part 1 e 2 fig 1 per 5 secondi La modalità TEST si disabilita comunque automaticamente dopo 15 minuti oppure chiu dendo il prelievo d acqua calda sanitaria nel caso vi sia stato un prelievo d acqua calda sanitaria sufficiente ad attivare la modalità Sanitario Regolazione pressione al bruciatore Questo apparecchio essendo del tipo a modulazione di fiamma ha due valori di p...

Page 5: ...llo scaldabagno sia regolare e che sia stata eliminata l aria dalle tubazioni Anomalia elettrodo di rivelazione accensione Controllare il cablaggio dell elettrodo e che lo stesso sia posizionato correttamente e privo di incrostazioni Valvola gas difettosa Verificare e sostituire la valvola a gas Cablaggio valvola gas interrotto Verificare il cablaggio Potenza di accensione troppo bassa Regolare la...

Page 6: ... Potenza Termica max kW 19 2 23 9 29 2 Potenza Termica min kW 7 1 8 8 10 7 Rendimento Pmax 88 5 88 7 88 9 Ugelli bruciatore G20 n x Ø 10 x 1 25 12 x 1 25 14 x 1 25 Pressione gas alimentazione G20 mbar 20 0 20 0 20 0 Pressione gas max al bruciatore mbar 13 0 14 0 15 0 Pressione gas min al bruciatore mbar 2 0 2 0 2 0 Portata gas max G20 m3 h 2 30 2 85 3 48 Portata gas min G20 m3 h 0 88 1 10 1 33 Uge...

Page 7: ...SI S 7 IT cod 3541A750 05 2011 Rev 00 5 4 Schema elettrico fig 15 Circuito elettrico 81 1kW L N 230V 50 Hz 16 N L ABM02 73 R1 R2 R3 R4 288 T T 344 4 3 2 1 44 38 ...

Page 8: ...vice Tool connection Indication during operation During a DHW demand generated by drawing domestic hot water the display detail 5 fig 1 shows the actual DHW outlet temperature Fault In case of a fault see cap 4 4 the display detail 5 fig 1 shows the fault code and during safety standby times the messages d3 and d4 2 3 Lighting and turning off Connection to the power supply During the first 5 secon...

Page 9: ... ap proved for operation with all the Cny flue configurations given on the dataplate Some configurations may be expressly limited or not permitted by law standards or local reg ulations Before installation check and carefully follow the instructions Also comply with the instructions on the positioning of wall and or roof terminals and the minimum distanc es from windows walls ventilation openings ...

Page 10: ...together for 5 seconds The TEST mode is automatically disabled in any case after 15 minutes or on stopping of hot water drawing if enough hot water was drawn to activate the DHW mode Adjustment of pressure at burner Since this unit has flame modulation there are two fixed pressure values the minimum and maximum which must be those given in the technical data table according to the type of gas Conn...

Page 11: ... burner ignition No gas Check the regular gas flow to the water heater and that the air has been elimi nated from the pipes Ignition detection electrode fault Check the wiring of the electrode and that it is correctly positioned and free of any deposits Faulty gas valve Check gas valve and replace it if nec essary Gas valve wiring disconnected Check the wiring Ignition power too low Adjust the ign...

Page 12: ... 3 12 6 Q Max heat output kW 19 2 23 9 29 2 Min heat output kW 7 1 8 8 10 7 Pmax efficiency 88 5 88 7 88 9 Burner nozzles G20 no x Ø 10 x 1 25 12 x 1 25 14 x 1 25 Gas supply pressure G20 mbar 20 0 20 0 20 0 Max gas pressure at burner mbar 13 0 14 0 15 0 Min gas pressure at burner mbar 2 0 2 0 2 0 Max gas delivery G20 m3 h 2 30 2 85 3 48 Min gas delivery G20 m3 h 0 88 1 10 1 33 Burner nozzles G31 n...

Page 13: ...SI S 13 EN cod 3541A750 05 2011 Rev 00 5 4 Wiring diagram fig 15 Electrical circuit 81 1kW L N 230V 50 Hz 16 N L ABM02 73 R1 R2 R3 R4 288 T T 344 4 3 2 1 44 38 ...

Page 14: ...e clignotant pendant la fonction anomalie combustion 10 Raccordement Service Tool Indication durant le fonctionnement L afficheur rep 5 fig 1 visualise la température actuelle de sortie de l eau chaude sa nitaire durant la demande d eau chaude sanitaire engendrée par l ouverture d un robinet d eau chaude sanitaire Anomalie En cas de panne voir cap 4 4 l afficheur rep 5 fig 1 visualise le code d er...

Page 15: ...é pour fonctionner avec toutes les configurations de con duits Cny indiquées sur la présente notice d instructions Toutefois il est possible que certaines configurations de sortie soient expressément limitées ou interdites par les tex tes réglementaires et ou la réglementation locale Avant de procéder à l installation véri fier et respecter scrupuleusement les prescriptions qui s y rapportent En o...

Page 16: ...e Mi nimum 0 Maximum 100 Pour désactiver le mode TEST appuyer simultanément 5 secondes sur les touches rep 1 et 2 fig 1 Le mode TEST se désactive automatiquement au bout de 15 minutes ou si l on inter rompt le prélèvement d eau chaude sanitaire pour autant que celui ci soit suffisant pour activer le mode Sanitaire Réglage de la pression au brûleur Cet appareil de type à modulation de flamme a deux...

Page 17: ...bles Solution A01 Le brûleur ne s allume pas Manque d alimentation de gaz Contrôler l arrivée régulière du gaz au chauffe bain et l élimination de l air dans les tuyaux Anomalie électrode d allumage de détection Contrôler que les électrodes soient correctement câblées positionnées et non incrustées Vanne à gaz défectueuse Contrôler et remplacer la vanne à gaz Câblage de la soupape de gaz interromp...

Page 18: ...ue mini kW 8 3 10 3 12 6 Q Puissance thermique maxi kW 19 2 23 9 29 2 Puissance thermique mini kW 7 1 8 8 10 7 Rendement Pmax 88 5 88 7 88 9 Gicleurs brûleur G20 nbre x Ø 10 x 1 25 12 x 1 25 14 x 1 25 Pression gaz alimentation G20 mbar 20 0 20 0 20 0 Pression gaz maxi au brûleur mbar 13 0 14 0 15 0 Pression gaz mini au brûleur mbar 2 0 2 0 2 0 Débit gaz maxi G20 m h 2 30 2 85 3 48 Débit gaz mini G...

Page 19: ...SI S 19 FR cod 3541A750 05 2011 Rev 00 5 4 Schéma électrique fig 15 Circuit électrique 81 1kW L N 230V 50 Hz 16 N L ABM02 73 R1 R2 R3 R4 288 T T 344 4 3 2 1 44 38 ...

Page 20: ...iciency Directive 92 42 Low Voltage Directive 73 23 amended by 93 68 Electromagnetic Compatibility Directive 89 336 amended by 93 68 EN FR Déclaration de conformité Le constructeur déclare que cet appareil est conforme aux directives CEE ci dessous Directives appareils à gaz 2009 142 Directive rendements 92 42 Directive basse tension 73 23 modifiée 93 68 Directive Compatibilité Electromagnétique 8...

Reviews: