14.

 

DIMENSIONS 

 

15.

 

TECHNICAL DATA 

Controlled device 

heating systems 

Supply voltage 

Thermostat - 3 V (2 pieces of alkaline AAA 
batteries) / receiver - 230 V 50 Hz 

Receiver output 

relay, voltage-free type, SPST 

Maximum load 

5 A 230 V 50 Hz 

Temperature measurement range 

°C...+99

 

°C

 

Temperature control range 

+5 

°C...+35

 

°C

 

Temperature control accuracy 

0.1°C

 

Temperature read-out accuracy 

0.1 

°C

 

Hysteresis range 

0.2 

°C... 10

 

°C with 0.1

 

°C step of the 

change or PWM mode 

Visual signalization 

backlit LCD 

Operating temperature 

+5 

°C...+45

 

°C

 

Storage temperature 

°C...+50

 

°C

 

Ingress protection rating 

IP20 

Color 

white/gray 

Installation method 

thermostat 

 stand / receiver 

 230 V 50 Hz 

plug socket 

Thermostat weight 

thermostat without batteries 

 120 g, 

Receiver 

 170 g 

Frequency of operation 

868 MHz 

Maximum power of transmission 

< 25 mW 

Warranty period 

2 years 

Thermostat class 

IV (PWM mode) 

Thermostat contribution to the seasonal 
energy efficiency of room heating 

2 % (PWM mode) 

 

 

16.

 

KIT CONTENTS 

 

Euroster 4010TXRX 

thermostat 

 

Euroster RX receiver 

 

2 pieces of alkaline AAA batteries 

 

thermostat stand 

 

Installation and Operation Manual with Warranty Certificate 

 

 

Summary of Contents for 4010TXRX

Page 1: ...nsor used in Euroster 4010TXRX enables temperature read out and programming accuracy of 0 1 C The preset temperature is modifiable within the range of 5 C 35 C 2 BASIC THERMOSTAT FUNCTIONS Does not re...

Page 2: ...antling the set make sure that the heating system is de energized Voltages hazardous to life may be present on receiver output cables power supply phase voltage therefore only qualified technicians ma...

Page 3: ...to the negative effect of moisture on the service life of the device 5 3 Insertion and replacement of batteries Place the batteries in the thermostat while observing the correct polarity There are ins...

Page 4: ...nal options for activating the heating algorithm are available hysteresis or PWM In the case of hysteresis the device is activated based only on a difference between the preset and current temperature...

Page 5: ...TTINGS 12 1 Establishing a connection between 4010TX thermostat and RX receiver or receivers pairing Each thermostat and each receiver has a unique number that distinguishes it from others It is not p...

Page 6: ...ngth The radio signal strength is indicated together with the reception of the transmitter signal Radio signal reception is indicated in green LED flashing three times stands for a very strong range t...

Page 7: ...ange or PWM mode Visual signalization backlit LCD Operating temperature 5 C 45 C Storage temperature 0 C 50 C Ingress protection rating IP20 Color white gray Installation method thermostat stand recei...

Page 8: ...nt and batteries and accumulators The proper disposal of waste equipment batteries and accumulators contributes to the prevention of consequences hazardous to the health of persons and nature resultin...

Reviews: