EUROSTER 4010TXRX Installation And Operation Manual Download Page 5

EUROSTER 4010TXRX 

 INSTALLATION AND OPERATION MANUAL

 

5

 

 

8.

 

TEST MODE (tSt) 

In the test mode, you may check the main parameters of the thermostat. In order to enter the 
test mode press and hold the 

central and left “ ” button for approximately 2 seconds. 

 

The following tests are available: 

 

internal sensor temperature measurement 

 

relay test - 

press the lower “ ” button repeatedly to switch the relay on/off,

 

 

backlight test 

 

press the upper “ ” button repeatedly to switch the backlight on/off.

 

 

radio communication level between the thermostat and the receiver (transmit and re-
ceive) 

 

press the “

” button.

 

9.

 

SWITCHING THE THERMOSTAT OFF 

When the switch is moved, the thermostat goes into frost protection mode.   icon appears on 
the  display.  Frost  protection  ensures  that  the  heating  is  switched  on  only  to  prevent  the 
temperature from dropping below 4 

°C.

 

10.

 

ERROR INDICATION 

OP 

 sensor missing or damaged 

SH 

 short-circuit of a sensor or a damaged sensor 

Err 1 

 internal error, remove and after a few moments reinstall the batteries 

 

 discharged batteries icon 

Err

 and   symbol 

 no radio communication. 

11.

 

MAINTENANCE 

Do  not  use  solvents  and  aggressive  detergents  to  clean  the  thermostat,  since  they  may 
damage the surface of the housing and the display. Clean the thermostat housing with a soft 
cloth. 

12.

 

RX RECEIVER SETTINGS 

12.1.

 

Establishing  a  connection  between  4010TX  thermostat  and  RX  receiver  or 

receivers (pairing) 

Each thermostat and each receiver has a unique number that distinguishes it from others. It is 
not  possible  for  any  thermostat  not  paired  with  the  particular  receiver  to  interfere  with  the 
operation of another pair or set. 
The  thermostat  may  be  paired  with  other  receivers  at  any  time.  A  blackout,  battery 
replacement as well as a complete reset of all thermostat settings do not affect the pairing of 
devices in any way. 
Pairing procedure: 

 

Enter the configuration mode in the thermostat  

 

Select the pairing mode (P)  

 

Press the central button 

 the display shows 0 

 

Insert the receiver into the plug socket  

 

Press the button on the receiver 3 times 

 the blue LED lights up. 

 

When the receiver is detected, the display shows OK and the digit 1 (first receiver) 

 

If  you  are  using  only  one  receiver,  press  the  central  button  and  exit  the  menu.  The 
pairing mode is ended. 

If you are going to pair multiple receivers (maximum 6), proceed as follows: 

 

When the first receiver is detected (digit 1 on the display), 

 

insert the second receiver into the plug socket. 

 

Press the button on the receiver 3 times 

 the blue LED lights up. 

 

When the receiver is detected, the display shows 2 (second receiver). 

 

Proceed  similarly  with  the  connection  of  subsequent  receivers,  then  press  the  central 
button and exit the menu.  

Caution! 

The pairing mode is available for 10 minutes after the receiver has been connected to 
the mains! 

Summary of Contents for 4010TXRX

Page 1: ...nsor used in Euroster 4010TXRX enables temperature read out and programming accuracy of 0 1 C The preset temperature is modifiable within the range of 5 C 35 C 2 BASIC THERMOSTAT FUNCTIONS Does not re...

Page 2: ...antling the set make sure that the heating system is de energized Voltages hazardous to life may be present on receiver output cables power supply phase voltage therefore only qualified technicians ma...

Page 3: ...to the negative effect of moisture on the service life of the device 5 3 Insertion and replacement of batteries Place the batteries in the thermostat while observing the correct polarity There are ins...

Page 4: ...nal options for activating the heating algorithm are available hysteresis or PWM In the case of hysteresis the device is activated based only on a difference between the preset and current temperature...

Page 5: ...TTINGS 12 1 Establishing a connection between 4010TX thermostat and RX receiver or receivers pairing Each thermostat and each receiver has a unique number that distinguishes it from others It is not p...

Page 6: ...ngth The radio signal strength is indicated together with the reception of the transmitter signal Radio signal reception is indicated in green LED flashing three times stands for a very strong range t...

Page 7: ...ange or PWM mode Visual signalization backlit LCD Operating temperature 5 C 45 C Storage temperature 0 C 50 C Ingress protection rating IP20 Color white gray Installation method thermostat stand recei...

Page 8: ...nt and batteries and accumulators The proper disposal of waste equipment batteries and accumulators contributes to the prevention of consequences hazardous to the health of persons and nature resultin...