EUROSTER 4010TXRX Installation And Operation Manual Download Page 2

EUROSTER 4010TXRX 

 INSTALLATION AND OPERATION MANUAL

 

2

 

 

DISPLAY 

 

A.

 

Radio communication symbol 

B.

 

Current temperature 

C.

 

Preset temperature 

D.

 

Active heating symbol 

 

 

 

4.

 

VISIBLE ELEMENTS OF RX RECEIVER 

 

a)

 

On/off switch for continuous operation 
of the heating device  

b)

 

Button with signaling LEDs used to 
enter settings  

c)

 

Output cable 

 

5.

 

INSTALLATION 

5.1.

 

Safety rules 

CAUTION! 

 

Prior  to  the  commencement  of  any  installation  works  read  this  manual 
carefully! Incorrect installation and improper use may lead to serious hazards 
to users or other persons and result in property damage! 

 

Prior to mounting or dismantling the set make sure that the heating system is 
de-energized! 

 

Voltages  hazardous  to  life  may  be  present  on  receiver  output  cables  (power 
supply  phase  voltage),  therefore  only  qualified  technicians  may  install  the 
thermostat! 

 

The  electric  connections  performed  and  cables  used  shall  be  adequate  to  the 
applied loads and must conform to all requirements! 

 

Do  not  install  the  set  in  rooms  with  increased  humidity;  protect  it  against 
water and other liquids! 

 

Do not install any unit showing signs of mechanical damage!

 

 

The thermostat is not a safety component. Additional protection devices must 
be  used  in  systems  prone  to  the  risk  of  damage  due  to  the  failure  of  control 
systems! 

 

The device is not intended for use by children! 

 

Should  there  be  any  problem  with  the  proper  operation  of  the  thermostat, 

Summary of Contents for 4010TXRX

Page 1: ...nsor used in Euroster 4010TXRX enables temperature read out and programming accuracy of 0 1 C The preset temperature is modifiable within the range of 5 C 35 C 2 BASIC THERMOSTAT FUNCTIONS Does not re...

Page 2: ...antling the set make sure that the heating system is de energized Voltages hazardous to life may be present on receiver output cables power supply phase voltage therefore only qualified technicians ma...

Page 3: ...to the negative effect of moisture on the service life of the device 5 3 Insertion and replacement of batteries Place the batteries in the thermostat while observing the correct polarity There are ins...

Page 4: ...nal options for activating the heating algorithm are available hysteresis or PWM In the case of hysteresis the device is activated based only on a difference between the preset and current temperature...

Page 5: ...TTINGS 12 1 Establishing a connection between 4010TX thermostat and RX receiver or receivers pairing Each thermostat and each receiver has a unique number that distinguishes it from others It is not p...

Page 6: ...ngth The radio signal strength is indicated together with the reception of the transmitter signal Radio signal reception is indicated in green LED flashing three times stands for a very strong range t...

Page 7: ...ange or PWM mode Visual signalization backlit LCD Operating temperature 5 C 45 C Storage temperature 0 C 50 C Ingress protection rating IP20 Color white gray Installation method thermostat stand recei...

Page 8: ...nt and batteries and accumulators The proper disposal of waste equipment batteries and accumulators contributes to the prevention of consequences hazardous to the health of persons and nature resultin...