Factory-established  thermostat-receiver  pairs  are  paired,  however,  pairing  may  be 
repeated if necessary.  

12.2.

 

Selecting operating mode 

While holding the  "B" button pressed, insert  the  receiver into the plug socket.  Depending on 
the mode set, the green or red LED lights up. Each time the button is pressed, the operating 
mode changes. When you select the mode, the receiver restores operation. 

Green  -  normally  open  mode  (COM 

  NO).  It  is  the  mainly  used  operation  mode.  While  the 

device operation indicator is active, the output cables are shorted. 

Red 

  normally  closed  mode  (COM 

  NC).  While  the  device  operation  indicator  is  active,  the 

output cables are opened. 

Caution! The factory default setting is (COM-NO). 

13.

 

FIRST START 

When inserted into the plug socket, the receiver indicates the relay operating mode. A flash of 
green LED 

 normally open mode (COM-NO), a flash of red 

 normally closed mode (COM-NC). 

Any change in the status of the thermostat (switching the heating on/off) is made immediately 
by the receiver, while the confirmation that the radio signal is received from the transmitter is 
repeated every 15 minutes. 

13.1.

 

Radio signal strength 

The  radio  signal  strength  is  indicated  together  with  the  reception  of  the  transmitter  signal. 
Radio signal reception is indicated in green. LED flashing three times stands for a very strong 
range, twice for a strong range, and once for sufficient range.   

13.2.

 

No radio communication 

If the communication between the thermostat and the receiver is interrupted (e.g. discharged 
batteries)  and  if  this  condition  lasts  for  60  minutes  (no  response  from  the  receiver),  the 
receiver switches to the frost protection mode. The heating device will be switched on every 3 
hours  for  20  minutes  to  prevent  the  rooms  from  being  cooled  down.  At  the  time  of  re-
establishing  communication  (replacement  of  batteries),  the  receiver  will  automatically  switch 
the system off and resume operation. 
If there is no radio communication, the green LED flashes rapidly. 

13.3.

 

Continuous operation of heating device (MAN) 

In  the  event  of  a  system  failure,  it  is  possible  to  manually  switch  on  the  heating.  Move  the 
switch on the RX receiver to the MAN position. Such status is indicated by a rapid flashing of 

the red LED. In addition, after a moment the display of the thermostat shows "On I" and 

 

symbol. 

13.4.

 

Receiver signaling table. 

Function 

Signaling 

Pairing 

Blue 

Reception of radio signal 

Green 

Lack of signal 

Green 

 flashing 

The heating device is switched on 

Red 

Manual operation in heating mode 

Red 

 flashing 

 

 

 

Summary of Contents for 4010TXRX

Page 1: ...nsor used in Euroster 4010TXRX enables temperature read out and programming accuracy of 0 1 C The preset temperature is modifiable within the range of 5 C 35 C 2 BASIC THERMOSTAT FUNCTIONS Does not re...

Page 2: ...antling the set make sure that the heating system is de energized Voltages hazardous to life may be present on receiver output cables power supply phase voltage therefore only qualified technicians ma...

Page 3: ...to the negative effect of moisture on the service life of the device 5 3 Insertion and replacement of batteries Place the batteries in the thermostat while observing the correct polarity There are ins...

Page 4: ...nal options for activating the heating algorithm are available hysteresis or PWM In the case of hysteresis the device is activated based only on a difference between the preset and current temperature...

Page 5: ...TTINGS 12 1 Establishing a connection between 4010TX thermostat and RX receiver or receivers pairing Each thermostat and each receiver has a unique number that distinguishes it from others It is not p...

Page 6: ...ngth The radio signal strength is indicated together with the reception of the transmitter signal Radio signal reception is indicated in green LED flashing three times stands for a very strong range t...

Page 7: ...ange or PWM mode Visual signalization backlit LCD Operating temperature 5 C 45 C Storage temperature 0 C 50 C Ingress protection rating IP20 Color white gray Installation method thermostat stand recei...

Page 8: ...nt and batteries and accumulators The proper disposal of waste equipment batteries and accumulators contributes to the prevention of consequences hazardous to the health of persons and nature resultin...

Reviews: