202203-577-ENG
User manual - X-PRO D200
P23
8. SAFETY CARD RUNNING (continued)
8.3. ALL FOUR LIGHTS ARE OFF
Defect
To check
Remedies
Electrical problem
No engine contact.
Turn the engine start key.
Dashboard fuse is out of order.
Change the fuse.
Battery connections are defective.
Check both battery terminals. Check
for the presence of grey green, brush
the terminals.
The battery is out of order or not
charged.
Contact the nearest technical service,
the battery must be changed, pay
attention to the polarities.
The power supply circuit must be cut
somewhere.
Contact the technical service.
The protective fuses on the card.
Change the faulty fuse.