User manual - Mixpro 14
202201-553-ENG
P14
4. USE OF THE MACHINE (continued)
4.5. ERROR CODES
The different error codes show up on the display (P).
CODES
DEFINITION
TO DO
No display.
Plug the machine into the power supply, assure the power supply is
230 V, verify the fuse in the electric box.
Emergency stop is
on.
Unlock the emergency stop button (AU).
Machine is in the
stop mode.
Switch the machine on by pressing on the button (1).
Default control
engine.
Set the machine to OFF for one minute and then switch it back on.
Safety Sensor
default.
Verify that the safety grating is properly closed.
Water pressure
default.
Only if (L5) is on.
Verify the water pressure on the manometer, check the water supply:
pressure > 2 bars or sufficient flow.
Start command
active when the
machine is switched
on.
Close the hose or switch the remote control to OFF.
Clean the flow meter (remove the piston).
If the problem persists or if in doubt on the good running of the machine, do not try to repair
it by yourself or to dismantle it.
Contact an authorized After-Sale Service or our hotline : +33 4 42 29 08 96.