1
SUITE INITIALIZATION
To initialize the suites, open the Concierge panel door, and press the CPU reset button. The
panel will restart the program.
Alternatively
, you may effect a Soft Start without having to open
the control panel. Enter User Number 2's code (default 1015 or 1020 depending on release date
of software), and press the PREV key. Display will show
SET DATE & TIME ?
. Press the
NO key and display will show
DAYLIGHT SAVING TIME?
. Press the YES key and
display will show
ARE YOU SURE ?
. Press the YES key and the panel will effect a Soft
Start.
After a few seconds, when the panel display shows
CONC 1.32
or similar, press the YES key.
The display will show
INITIALIZE SUITES ?
.
Press the YES key again and the panel will show
SUITE INITIALIZATION
.
Press the YES key and the panel will show
DEBUG MODE ?
.
Press the YES key and the panel will show
MAX RETRIES 3
. Press the ENTER key. The
panel will show
LOG RETRIES ?
.
Press the NO key. The panel will show
HIGH SPEED COMMS ?
.
Press the YES key. The panel will show
OVERWRITE SUITE IDS ?
. If the panel has
not
been cold start zapped
(thus removing the IDS from the panel) press the YES key. This will
transfer the IDS from the panel to the suite plates. If, however, the panel has been cold started
with zap then press the NO key and the ids stored in the suite plates will be transferred back to
the concierge panel. The panel will display
MAX SUITE NO. = 255
.
Enter the number of the highest keypad address and press the ENTER key. The panel will now
start scanning for suites and any suite number that it finds will have an
*
displayed after it. This
means that suite is now on-line.
When the maximum suite number is reached the panel will display
ON LINE O ----> N
where
the O is the old suite number count and the N is the new suite number count. Press the YES key
to accept the count or the NO key to repeat the process.
The panel will now display a number of messages to which you may press the ENTER key and
finally the panel will end with
BUSY ... RESCHEDULING
.
The initialization of the suites is complete.