Page 1: ...CARBOROUGH ONTARIO CANADA M1B 3L6 TEL 416 754 4313 FAX 416 754 8992 E MAIL admin intramerica biz INSTALLATION AND OPERATION MANUAL FOR SUITEPLEX MODEL 3850 CONCIERGE CONTROL PANEL C COPYRIGHT EUROPLEX...

Page 2: ...TENTS HOW TO INITIALIZE THE SUITES SYSTEM OPTIONS NOTE CONCIERGE PANEL USER OPTIONS CONCIERGE PANEL SINGLE KEY FUNCTIONS SUITE PANEL USER OPTIONS SUITE PANEL SINGLE KEY FUNCTIONS FUNCTION This documen...

Page 3: ...he NO key The panel will show HIGH SPEED COMMS Press the YES key The panel will show OVERWRITE SUITE IDS If the panel has not been cold start zapped thus removing the IDS from the panel press the YES...

Page 4: ...Y OPTION 1 DISARM DISARM Functions 3 options 1 1 Disarm Concierge to accept alerts or Disarm the Concierge Panel 1 2 Disarm Suite to accept alerts or Disarm specified suites 1 3 Acknowledge Alarms to...

Page 5: ...e g the master 7 2 Sub menu SYSTEM SET UP 2 options 7 2 1 SET ZONES 7 2 2 SET VARIABLES 7 3 Sub menu SERIAL SET UP Allows set up of the serial channel 1 serial channel 2 parameters 7 3 1 Baud Rate 7...

Page 6: ...erts the user that a battery test has been done and causes an alarm if the battery is faulty 12 5 SPARE MODE Literal available for mode command 13 6 SPARE MODE Literal available for mode command 14 7...

Page 7: ...g the user to enter the suite number and then executing the Evening Arm literal on that suite The QUIT key exits 3 Remote Sleep Arm This routine allows the user to Sleep Arm any on line suite by promp...

Page 8: ...when finished The revised literal will now be stored in memory 7 Set up Test Option Pressing the NEXT key or the PREV key moves forwards or backwards respectively through the 5 options available and t...

Page 9: ...key to exit the option 7 2 2 Set Variables The user is prompted with the variable and it s default value The new value should be entered To select the next variable the NEXT key should be pressed Pre...

Page 10: ...sing the YES ENTER or QUIT key has the effect described in 7 3 1 Any integer less than 256 will be accepted 7 4 Up Download Data 7 4 1 Upload Data i Once selected the panel will suspend normal operati...

Page 11: ...selects the option The QUIT key exits the routine 9 1 View Log This causes all events logged by the Concierge panel and each Suite panel to be displayed on the Concierge Panel displayed in reverse ch...

Page 12: ...FROM SUITE NO When this is entered the next prompt is TO SUITE NO When this has been entered check is carried out to ensure that the maintenance code has been set 10 1 and if that is the case then the...

Page 13: ...d as in 14 1 By accepting the default values the message which was sent to all suites will be cleared otherwise the message will be cleared from the displays of the suites in the specified range The Q...

Page 14: ...mes codes and options of any user on the suite The service user can change it s own name and code and the name and the code of other suite users except user 1 The other suite users are allowed to chan...

Page 15: ...d read ii Otherwise press the ENTER key and go to iii ii The previous name which may be the default name is displayed in the edit mode This name may be changed by first deleting it using the SHIFT key...

Page 16: ...NGLE KEY FUNCTIONS KEY OPERATION FIRE Causes alarm and sets relay on suite PANIC Alarm and relay EMERG Alarm relay and buzzer These keys have to be depressed for 3 seconds or pressed 3 times in succes...