MAINTENANCE
24
H Series
Vent Free Fireplace Rev #12042020 European
Home
.com
A qualified service agency should conduct an annual inspection and maintenance of your
H Series
Vent Free Gas
Fireplace to keep it running safely. The following procedures should be performed only by a qualified service
person. The gas supply should be turned off whenever a maintenance procedure is performed. All parts of the
fireplace that are removed for servicing must be replaced prior to operation.
Cleaning the Media and Burner
With all parts of the fireplace at room temperature, carefully remove and clean the fire media with a soft bristled
brush.
Lift off the hearth panel and clean the burner surface with a brush and clean the rest of the burner module,
including the pilot burner, with a vacuum cleaner. After lifting off the Hearth Panel, ensure that the Primary Air
Openings (shown below, at the end of each Burner Inlet Tube) remains free of dust or debris. These openings
may cleaned with a vacuum cleaner or brush.
Primary Air Openings
Burner Inlet Tubes
Failure to keep the primary air opening of the burner clean may result in sooting
and property damage.
W
ARNING
W
ARNING
Burner Close-up