background image

 

53

 

Error out 14-16 

The

 

connection

 

is

 

named

 

"ERROR

 

OUT

 

(MAX

 

1A)"

 

on

 

the

 

adhesive

 

sticker.

  

The

 

output

 

is

 

potential

free

 

and

 

has

 

both

 

an

 

NC

 

and

 

an

 

NO

 

connection.

 

It

 

can

 

be

 

used

 

to

 

get

 

a

 

signal

 

to

 

an

 

external

 

unit

 

or

 

to

 

a

 

GSM

 

unit.

 

The

 

output

 

can

 

be

 

loaded

 

with

 

max

 

1A

 

During

 

normal

 

operations

 

with

 

no

 

alarm,

 

there

 

is

 

contact

 

between

 

terminals

 

15

 

and

 

16.

 

In

 

the

 

event

 

of

 

an

 

alarm

 

or

 

power

 

failure

 

there

 

is

 

contact

 

between

 

14

 

and

 

15

  

 

 

Error

 

or

 

power

 

failure

 

(NC)

   

            

Normal

 

operations

 

(NO)

 

 

 

 

 

 

 

 
 

Digital input 17-18

 

Connection

 

named

 

"EXTRA

 

DIGITAL

 

IN"

 

on

 

the

 

adhesive

 

sticker.

 

 

The

 

input

 

should

 

be

 

potential

free

 

and

 

has

 

different

 

functions

 

depending

 

on

 

what

 

settings

 

are

 

chosen

 

in

 

the

 

display.

 

From

 

program

 

version

 

1.4

 

the

 

set

 

function

 

is

 

standby.

 

If

 

the

 

input

 

is

 

closed

 

the

 

heat

 

pump

 

and

 

electric

 

heater

 

will

 

be

 

blocked

 

until

 

the

 

input

 

is

 

opened

 

again.

 

When

 

closing

 

the

 

input

 

below

 

display

 

text

 

will

 

be

 

activated.

 

 

****SYSTEM OK***** 
Standby mode active 
Heatpump/El.heater 
blocked. Time 26min 

 

Summary of Contents for Exotic Compact 10

Page 1: ...Exotic Compact C 1308 118 ver 1 3 EN Installation and user guide for Exotic Compact C For software version 1 4 With flow reduce valve...

Page 2: ...tant 17 In practice 17 Hot water 18 Hot water settings 19 Base heat 21 Summer charging 21 Display 22 Overview 22 Menu modes 22 Menu modes 23 Adjust a setting 23 Menu tree 24 Main menu 24 Menu Settings...

Page 3: ...erminal blocks 49 Block A 230V 49 Block B extra low voltage 50 Communication 1 2 50 Outdoor sensors 3 4 50 Room sensors 5 8 51 Current transformers 10 13 accessories 52 Error out 14 16 53 Digital inpu...

Page 4: ...sis to the finished heat pump are monitored to continually maintain quality The chassis of the heat pump including all screws and rivets are manufactured from stainless steel which requires minimum ma...

Page 5: ...nsor room sensor Safety regulations The following safety regulations must be observed when handling installing and using the product An omnipolar switch should be installed on the power supply cables...

Page 6: ...lve HP return Cold water in cu22 Hot water out cu22 Drainage valve Brine in Circuit board for tank unit Fuses heat pump elec heater Contactor for electric heater Emergency heat switch Reset overheatin...

Page 7: ...ndenser High pressure switch Service outlet high pressure Service outlet low pressure Low pressure switch Brine circulation pump Brine out Hot gas pipe Condenser Filter receiver Compressor Heat pump c...

Page 8: ...this curve yourself It is important to make sure that the heating curve is set properly for your own comfort but also to ensure the overall efficiency of the heating system Upper tank section The upp...

Page 9: ...oor heating system the water will not need to be as hot to achieve sufficient heating Based on all of these parameters which vary from house to house the settings will be unique in each case We call t...

Page 10: ...outside the Exotic Compact unit sends 55 C water to the radiators When you adjust this point you change the angle of the entire heating curve The biggest changes occur when outdoor temperatures are co...

Page 11: ...nt at all If you increase this value the curve moves upwards i e becomes warmer and if you reduce this value the temperature drops This setting is primarily used when you feel that it is too cold or w...

Page 12: ...ouse During summer time when heat is in off mode both circulation pump and mixing valve which determines the temperature to the heating system will be run periodically in order to prevent sticking If...

Page 13: ...or temperature is 0 C cracking the curve If you feel that there isn t enough heating when it is around 0 C outside but it is otherwise sufficient you can increase this setting somewhat Adjusting the c...

Page 14: ...nit stops sending water to your heating system If you activate basement heating Exotic Compact will continue to send water at the temperature you set even if the outdoor temperature is high Activate b...

Page 15: ...t unlock this function in the installer s menu in order for you to be able to view it Setting a maximum temperature also allows you to protect your underfloor heating system against excessively high t...

Page 16: ...g For each 1 10 of a degree 0 1 C that the current room temperature deviates from the set temperature the temperature in your heating system drops by approximately 4 C Block temporarily The button pla...

Page 17: ...s warmer than necessary and therefore has a lower degree of efficiency The best savings for your heating system come from setting the water temperatures as low as possible In practice It can take a lo...

Page 18: ...ptimal savings How hot water is produced The Exotic Compact does not have any container or coils with hot water inside the tank but fresh hot water is produced continuously using a special hot water e...

Page 19: ...time to try to heat the water in the upper tank When you use hot water from the Exotic Compact unit primarily when showering or filling the bathtub the temperature in the upper and lower section will...

Page 20: ...or the heat pump to increase the tank temperature No electric heater is used for this function which implies lower costs Upper tank temperature You can set the temperature that you want to be maintain...

Page 21: ...ring the summertime your house needs very little heating or none at all In order to increase the running time for the heat pump and increase the amount of domestic hot water in the summertime you can...

Page 22: ...se up and down through the different menu trees but also to increase or decrease a value for the various settings Left right arrow Use the right arrow to move up one step in the menu tree when there a...

Page 23: ...ngs submenu When you are in a settings display there is either a number or a yes no option All of the adjustable parameters have an arrow in front of them To activate the setting press the right arrow...

Page 24: ...on time Service Settings This is where you can adjust the settings for the heating curve among other things and set the room temperature and the domestic hot water temperature etc Present values This...

Page 25: ...ating and domestic hot water Function key Menu for setting of functions for the button on the room sensor Pool heating If the accessory Pool heating is installed this menu will be activated Please rea...

Page 26: ...e 17C Heating curve point C indicates the outdoor temperature at which the heat should stop being sent mixed to the heating system Above this temperature the mixing closes completely and the radiator...

Page 27: ...lower tank section so called floating condensation Since the lower section of the tank is used to preheat the hot water the temperature should not be too low Base heat is the lowest temperature to whi...

Page 28: ...ave an open fireplace placed in the same room as the sensor When you add heat to the room with the fire place the sensor will stop the heat to the complete heating system i e all rooms will be affecte...

Page 29: ...en the current value and the nominal value Only displayed if room sensors are installed Heating system 1 Heat ON OFF Act 36 2C Nom 35 7C Outdoor temp 11 1C Current information for your heating system...

Page 30: ...6C Current status of the mixing valve motor which ensures that the right temperature is sent to your heating system The mixing motor opens and closes continuously so that the difference between the c...

Page 31: ...of the 3 phases are being charged by the electric heater and with how much power During charging a signal will flash alternately between on and L1 2 3 In the display example on the right phase L1 is...

Page 32: ...cheaterinit Before the heating system can take water energy from the upper tank section a certain length of time must have passed from when the need arose the standard is 3 hours This gives the heat p...

Page 33: ...brine can have before the system stops and an alarm is triggered Your installer sets this parameter which depends on how much anti freeze liquid there is in the system Hot gas temp 95C Max allowed tmp...

Page 34: ...code for the heat pump module in order for it to communicate correctly with the tank section Only displayed if the heat pump is installed Heat pump total ope ration 23547h Compressor total op ration 1...

Page 35: ...p module it runs automatically as an electric boiler This display provides information about the electrical power that the electric heater is currently using Only displayed if heat pump is not install...

Page 36: ...ection and the heat pump module charge pump will start to check the temperatures in order to optimise operations during startup This information appears in the display during that time SYSTEM OK Heat...

Page 37: ...ated and 2 of the alarms are still active ERROR Error total 3 Active errors 2 Scroll with up down ERROR 1 3 Room sensor 1 Type Short circuit Error must be fixed ERROR 2 3 Brine in sensor Type Open Not...

Page 38: ...sors used for measuring the amount of energy in your heating system This type of error can be either a short circuit or a failure in the sensor or cable Only displayed if the energy meter accessory is...

Page 39: ...ipe in the heat pump module see the overview diagram at the beginning of this manual This type of error can be either a short circuit or a failure in the sensor or cable Only displayed if heat pump mo...

Page 40: ...ase L1 missing in heat pump Error must be fixed Thiserroroccursbecauseonephase L1 ismissingfortheheatpump module Checkthemainfuses ERROR 1 1 High pressure switch Heat pump tripped Error must be fixed...

Page 41: ...ller has set the lowest allowable temperature depending on how much anti freeze was used Contact the service department in the event of repeated alarms ERROR 1 1 Low flow brine circuit Error must be f...

Page 42: ...basic design heating pipes are mounted for a top connection However both pipes can be easily reversed to allow for a bottom connection The flow line for the heating system is mounted directly on the m...

Page 43: ...are designed with a cc measurement of 55 mm in order to make installing a combination of valves easy Note that the safety valve does not need to be installed as the exchanger volume is below 1 litre...

Page 44: ...must be insulated to prevent ice or condensation from forming Brine fluid The brine medium should contain an antifreeze medium e g bio ethanol to maintain fluidity down to temperatures of 15 C Collec...

Page 45: ...for brine medium CompletekitasshowncanbeorderedfromEuronom item no 1921062 No Description 1 Brine to heat pump in 2 Brine from heat pump out 3 Fill coupling including valves dirt filter 4 Safety valve...

Page 46: ...ifference of 3 C between the brine in out is the ideal If the difference is too high the system will issue a low brine flow alarm The diagram below shows the drop in pressure for the evaporator and th...

Page 47: ...e terminal blocks and how the connection should be set up The terminal blocks are divided into blocks called A B C D E and F Note that this manual only describes how to connect standard components i e...

Page 48: ...m power based on a main fuse in the system The table below provides a rough guide to power usage with different electric heater stages connected to the heat pump Note that the element in the electric...

Page 49: ...that the installation is correct by pulling hard on the cable See also the diagrams below Also note the marking on the adhesive sticker regarding the upper and lower connection Block A 230V The only...

Page 50: ...catch to be opened tools are not needed Two spring loaded terminal blocks are located inside the sensor Press the release button and insert the stripped cable to make the connection Cable to the outd...

Page 51: ...addition there is a button on the room sensor that can be used for different functions e g extra hot water which can be set in the display In order for the room sensor to work well the sensor should...

Page 52: ...s that the 3 phases are distributed as evenly as possible Installing the current transformers is recommended but not required It is possible to limit the maximum electrical power for the electric heat...

Page 53: ...er failure there is contact between 14 and 15 Error or power failure NC Normal operations NO Digital input 17 18 Connection named EXTRA DIGITAL IN on the adhesive sticker The input should be potential...

Page 54: ...e selected language with the ENTER button After selecting the language you will come to menu where you can adjust the settings Use the arrow buttons to move to the following location Settings For the...

Page 55: ...he need In the event of an alarm excessive temperature on the heat pump or when the compressor is blocked the time delay is lifted automatically Only displayed if heat pump module is installed Current...

Page 56: ...heat pump is installed Language ENGLISH Setting the language for the display screen Factory reset WARNING ALL SETT INGS WILL BE LOST Reset No This menu is used to reset all of the settings to the fact...

Page 57: ...menu is used primarily by service technicians and should not be used unless you have a thorough knowledge of the system Use the arrow buttons to move to the following location Settings Enter access co...

Page 58: ...ine flow al arm when temp diff above 8C Alarm setting for low brine flow through the heat pump module i e the temperature differential is too large Max flow temperature from heat pump 58C Max allowed...

Page 59: ...charge pump Integral min 5000 PI regulator charge pump Min flow 190 l h Note that the settings in the remaining displays should not be adjusted before contacting Euronom The charge pump that moves th...

Page 60: ...53C C 15 2A D 12C E 14C F 115C G 16C H 99 I 1250l The number 1 in 1 5 indicates which display is shown 1 5 is the last alarm that was logged The letters A I have the following meanings according to th...

Page 61: ...default offset value is always 0 0 C Settings Calibration Error logs Boiler Calibration Heat pump Manual operation Calibration Boiler Display Description Comments Tank sensor lower Actual 34 6C Offse...

Page 62: ...mp sensor Actual 44 6C Offset 0 0C Calibrating primary flow temp sensor Return flow temp sensor Actual 30 6C Offset 0 0C Calibrating flow temp sensor Hot gas sensor Actual 94 3C Offset 0 0C Calibratin...

Page 63: ...radiator pump for heating system 1 Circulation pump hot water exchanger Off On Manual operation of the circulation pump that moves the hot water through the hot water exchanger Mixing valve motor Heat...

Page 64: ...heater stages 6 kW 2 kW phase and current value on current sensors L1 L2 and L3 When turning on the system the current will increase by about 8 7A per phase is current sensors are installed External...

Page 65: ...26 48 0 98 3 5 1 5 91 35 1 38 28 44 1 100 3 3 0 5 65 36 1 33 30 40 5 102 3 1 1 5 40 37 1 28 32 37 2 104 2 9 2 5 17 38 1 24 34 34 2 106 2 8 3 4 95 39 1 19 36 31 5 108 2 6 4 4 73 40 1 15 38 29 1 110 2...

Page 66: ...ve Extra connections 3 pc DN20 out Run as electric boiler Yes Connection brine Hose 28 mm connection right or left Pressure drop evaporator 1 3 kPa 2 2 kPa 3 2 kPa 4 3 kPa Pressure drop condenser 2 0...

Page 67: ...uit aerated OK CUSTOMER Circulation in brine loop OK Name Speed circulation pump brine loop 1 2 3 Address Speed radiator pump if not variable _________ Postal address Fuse heat pump _________A Telepho...

Page 68: ...68 Electrical diagram tank unit...

Page 69: ...69...

Page 70: ...70...

Page 71: ...71 Electrical diagram heat pump module...

Page 72: ...72...

Page 73: ...2500 521142500 521142500 Hot gas sensors 521137800 521137800 521137800 521137800 Outdoor sensor 521137600 521137600 521137600 521137600 Room sensor 521137500 521137500 521137500 521137500 Sensors Tank...

Page 74: ...74 Visiting and delivery address Franska v gen 12 393 56 KALMAR SWEDEN Telephon 46 0 480 221 20 Telefax 46 0 480 870 17 www euronom se info euronom se...

Reviews: