Menu – Heating/Hot water
Display
Description
Comments
Chosen function room
sensor button:
Extra hot water
Time:50min Act:Yes
►
↓
When
using
the
function
button
on
the
room
sensor
for
extra
hot
water
this
display
will
be
available.
Here
you
can
see
the
set
time
for
extra
hot
water
and
also
if
the
function
is
activated
or
not.
Only
displayed
if
extra
hot
water
function
is
chosen.
Chosen function room
sensor button:
Block room sensor
Time:4h Act:Yes
►
↓
When
using
the
function
button
on
the
room
sensor
for
the
function
deactivate
room
sensor
this
display
will
be
available.
Here
you
can
see
the
set
time
for
blocking
of
the
sensor
and
also
if
the
function
is
activated
or
not.
Only
displayed
if
deactivate
room
sensor
function
is
chosen.
Chosen function room
sensor button:
Reset errors
Active: No
►
↓
When
using
the
function
button
on
the
room
sensor
for
resetting
errors
this
display
will
be
available.
To
test
the
function
push
the
button
and
make
sure
the
“Active”
changes
from
“No”
to
“Yes”
Only
displayed
if
reset
error
function
is
chosen.
Mixing valve motor 1
■
Opens
□
Closing
□
Waiting
□
Off
Difference: -0.6C
►
↓
Current
status
of
the
mixing
valve
motor
(which
ensures
that
the
right
temperature
is
sent
to
your
heating
system).
The
mixing
motor
opens
and
closes
continuously
so
that
the
difference
between
the
current
value
and
the
nominal
value
is
0.
In
the
"Waiting"
mode,
the
system
waits
to
see
what
kind
of
effect
the
previous
adjustment
(opening
or
closing)
has
had.
If
the
status
is
"Closed",
the
mixing
is
completely
closed
and
no
heat
is
needed.
Hot water tapping
ongoing:
□
Yes
■
No
Length of last tapp-
ing: 6min 27sec
►
↓
Information
about
when
hot
water
is
used
and
how
long
since
the
last
tapping.
Temp lower tank part
Actual: 38.2C
Nominal: 40.0C
Startdiff HP: 5.0C
►
↓
Information
about
status
of
lower
tank
section.
Actual
value
is
the
current
temperature
in
the
lower
section
of
the
tank.
Nominal
value
is
the
temperature
that
the
system
has
calculated
that
the
heat
pump
must
maintain
in
the
lower
tank
section
in
order
to
supply
the
required
heating
for
the
house.
This
temperature
varies
depending
on
the
outdoor
temperature,
room
temperature
and
how
the
heating
curve
is
set.
Startdiff
HP
is
the
so
‐
called
hysteresis,
or
the
difference
from
the
nominal
value
required
for
the
heat
pump
to
start
heating
the
tank
section.
In
the
current
display,
the
temperature
must
drop
by
at
least
5
°
C
from
the
nominal
value,
i.e.
a
restart
occurs
when
the
lower
tank
section
reaches
35.0
°
C.